User manual WHIRLPOOL AKT 464 NB PROGRAM CHART

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual WHIRLPOOL AKT 464 NB. We hope that this WHIRLPOOL AKT 464 NB user guide will be useful to you.

Lastmanuals help download the user guide WHIRLPOOL AKT 464 NB.


Mode d'emploi WHIRLPOOL AKT 464 NB
Download
Manual abstract: user guide WHIRLPOOL AKT 464 NBPROGRAM CHART

Detailed instructions for use are in the User's Guide.

[. . . ] Make sure the room is well-ventilated, or install an extractor hood with exhaust duct. In case of prolonged use, additional ventilation may be necessary (by opening a window or increasing the hood extraction speed). After use, make sure the knobs are in off position and close the main gas supply cock or the gas cylinder valve. Overheated oils and fats catch fire easily. [. . . ] Before installation, make sure that: - the local gas delivery conditions (nature and pressure) are compatible with the settings of the hob (see the rating plate and injector table); - the outer surfaces of the furniture or appliances adjacent to the hob are heat resistant according to local regulations; - combustion products are discharged outdoors through specific hoods or wall and/or window mounted electrical fans. WARNING - If the information in this manual is not followed exactly, a fire or explosion may result causing property damage or injury. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this appliance. Doing so may result in carbon monoxide poisoning and overheating of the hob. The Manufacturer declines all responsibility for inappropriate use or incorrect setting of the controls. - The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or with lack of experience and knowledge of the appliance, unless supervised or previously instructed in its use by those responsible for their safety. - Young children should be kept away from the appliance and supervised to ensure that they do not play with it. The gas supply system must comply with local regulations. You can find specific local regulations for some countries in the paragraph “Reference to Local Regulations”. If no information concerning your Country is given, please ask details to your Installer. • The connection of the hob to the gas pipe network or gas cylinder must be made by means of a rigid copper or steel pipe with fittings complying with local regulations, or by means of a continuous-surface stainless steel hose complying with local regulations. The maximum length of the hose is 2 linear metres. • Connect elbow (A)* or (B)* supplied with to the hob inlet main pipe and interpose the washer (C) supplied, in compliance with EN 549. * Use elbow (A) for France and elbow (B) for all other destinations. If there are other fuel burning appliances in the same room B. S. 5440 - Part 2 should be consulted to determine the air vent requirements. If the appliance is installed in a cellar or basement, it is advisable to provide an air vent of 65 cm, irrespective of the room volume. Gas Safety Regulations The law requires that all gas appliances are installed by competent persons in accordance with the current gas safety regulations. Failure to install appliances correctly may lead to prosecution. It is in your own interest, and that of safety, to ensure that the law is complied with. The hob should be installed in accordance with the Gas Safety (Installation and Use) Regulations, the Building Regulations issued by the Department of the Environment and the Building Standard (Scotland) (Consolidation) Regulations, issued by the Scottish Development Department. In the G. B. , CORGI registered installers work to safe standards of practice. If the appliance is intended to operate with a different gas from the gas type stated on the rating plate and information label on the top of the hob, change the injectors. Remove the information label and keep it with the instructions booklet. Use pressure regulators suitable for the gas pressure indicated in the Instruction. • The gas nozzles must be changed by After Sales Service or a qualified technician. • Nozzles not supplied with the appliance must be ordered from After Sales Service. [. . . ] • The burner openings are not clogged near the thermocouple. • The end of the safety device is not dirty. • The minimum gas setting is correct (see relevant paragraph). The containers are not stable Check that: • The bottom of the container is perfectly flat • The container is centered on the burner. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL AKT 464 NB

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual WHIRLPOOL AKT 464 NB will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag