If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual WHIRLPOOL AKT 616/NB. We hope that this WHIRLPOOL AKT 616/NB user guide will be useful to you.
Lastmanuals help download the user guide WHIRLPOOL AKT 616/NB.
Manual abstract: user guide WHIRLPOOL AKT 616/NBPROGRAM CHART
Detailed instructions for use are in the User's Guide.
[. . . ] Do not repair or replace any part of the appliance unless specifically stated in the user manual.
TECHNICAL INFORMATION FOR THE INSTALLER
• • This product can be embedded in a worktop 20 to 60 mm thick. If there is no oven beneath the hob, insert a separator panel that has a surface at least equal to the opening in the work surface. This panel must be positioned at a maximum distance of 150 mm below the upper surface of the work surface but, in no case less than 20 mm from the bottom of the hob. In the case that you intend to install an oven beneath the hob, make sure that it is manufactured by Whirlpool and equipped with a cooling system. [. . . ] Do not use this appliance as a space heater to heat or warm the room. Doing so may result in carbon monoxide poisoning and overheating of the hob. The Manufacturer declines all responsibility for inappropriate use or incorrect setting of the controls. - The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or with lack of experience and knowledge of the appliance, unless supervised or previously instructed in its use by those responsible for their safety. - Young children should be kept away from the appliance and supervised to ensure that they do not play with it.
GAS CONNECTION WARNING
• • This operation must be performed by a qualified technician.
The gas supply system must comply with local regulations. You can find specific local regulations for some countries in the paragraph “Reference to Local Regulations”. If no information concerning your Country is given, please ask details to your Installer. • The connection of the hob to the gas pipe network or gas cylinder must be made by means of a rigid copper or steel pipe with fittings complying with local regulations, or by means of a continuous-surface stainless steel hose complying with local regulations. The maximum length of the hose is 2 linear metres. • Connect elbow (A)* or (B)* supplied with to the hob inlet main pipe and interpose the washer (C) supplied, in compliance with EN 549. * Use elbow (A) for France and elbow (B) for all other destinations. Use pressure regulators suitable for the gas pressure indicated in the Instruction. • The gas nozzles must be changed by After Sales Service or a qualified technician. • Nozzles not supplied with the appliance must be ordered from After Sales Service. • Adjust the minimum setting of the taps. NOTE: when liquid petroleum gas is used (G30/G31), the minimum gas setting screw must be tightened as far as it will go. IMPORTANT: should you experience difficulty in turning the burners knobs, please contact the After Sales Service for the replacement of the burner tap if found to be faulty.
The installation and maintenance of the appliance must be carried out by a qualified skilled technician in accordance with the regulations in force, and in particular: - Decree of 2 August 1977 Technical and Safety Rules applicable to fuel gas and liquefied hydrocarbon installations located within residential buildings and outbuildings. - Standard DTU P 45 - 204 Gas installations (formerly DTU no. 61-1 - Gas installations April 1982 + supplement no. - Departmental Health Regulations For appliances connected to the mains electricity supply. - Standard NF C 15-100 Low-voltage electrical installations - Standards.
Ensure that the installation and gas connections are performed by a qualified technician, following the manufacturer’s instructions and in compliance with current local safety regulations.
AFTER-SALES SERVICE
Before calling the After-Sales Service, make sure you can give the following information: - type of fault or problem; - exact model (written on the label affixed to the instruction/warranty); - service number that follows the word SERVICE on the rating plate under the hob and on the label affixed to instruction/warranty; - your complete address and phone number. If any repairs are required, please contact an authorised After-Sales Service, as indicated in the warranty.
TROUBLESHOOTING GUIDE
If the hob will not operate correctly, before calling the After-Sales Service, refer to the Troubleshooting Guide to determine the problem. [. . . ] - Two burners simultaneously for one receptacle (e. g. fish kettle).
INJECTORS TABLE Burner
4 ring burner Semi-rapid Auxiliary
CATEGORY II2E+3+
Injector Rated thermal Rated marking flow rate consumption kW
4 ring 139 97 74 B 139 97 74 B 95 65 50 95 65 50 3. 50 1. 65 1. 00 3. 50 1. 65 1. 00 3. 50 1. 65 1. 00 3. 50 1. 65 1. 00 333 l/h 157 l/h 95 l/h 388 l/h 183 l/h 111 l/h 254 g/h 120 g/h 73 g/h 250 g/h 118 g/h 71 g/h
Pot Ø
From 24 to 26 cm From 16 to 22 cm From 8 to 14 cm
Type of gas used
Type of burner
Reduced heat capacity kW BE
2. 20 0. 45 0. 35 2. 20 0. 35 0. 30 1. 90 0. 35 0. 30 1. 90 0. 35 0. 30
Gas pressure mbar min. max.
FR
2. 20 0. 35 0. 30
NATURAL GAS (Methane) G20
Semi-rapid Auxiliary 4 ring
17
20
25
NATURAL GAS (Methane) G25 LIQUEFIED PETROLEUM GAS (Butane) G30 LIQUEFIED PETROLEUM GAS (Propane) G31
Semi-rapid Auxiliary 4 ring Semi-rapid Auxiliary 4 ring Semi-rapid Auxiliary
20
25
30
20
28-30
35
HOW TO USE THE HOB WARNING
Do not let the burner flame extend beyond the edge of the pan.
25
37
45
IMPORTANT: WHEN THE HOB IS IN USE, THE ENTIRE HOB AREA MAY BECOME HOT. • To ignite one of the burners, turn the relative knob anti-clockwise to the maximum flame setting. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL AKT 616/NB
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.