User manual WHIRLPOOL AKT 923/IXL PROGRAM CHART

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual WHIRLPOOL AKT 923/IXL. We hope that this WHIRLPOOL AKT 923/IXL user guide will be useful to you.

Lastmanuals help download the user guide WHIRLPOOL AKT 923/IXL.


Mode d'emploi WHIRLPOOL AKT 923/IXL
Download
Manual abstract: user guide WHIRLPOOL AKT 923/IXLPROGRAM CHART

Detailed instructions for use are in the User's Guide.

[. . . ] GB AKT 923 BUILT-IN GAS HOB The use of a gas appliance produces heat and humidity in the room. Make sure the room is well-ventilated, or install an extractor hood with exhaust duct. In case of prolonged use, additional ventilation may be necessary (by opening a window or increasing the hood extraction speed). After use, make sure the knobs are in off position and close the main gas supply cock or the gas cylinder valve. [. . . ] • After connection to the gas supply, check for leaks with soapy water. Light up the burners and turn the knobs from max position flame stability. to minimum position to check A C C B C 5019 319 01735 Manufacturer: Whirlpool Europe S. r. l. Borghi, 27 21025 Comerio (VA) ITALY ELECTRICAL CONNECTION WARNING WARNING This operation must be performed by a qualified technician. • • • The electrical connections must comply with local regulations. The earthing of this appliance is compulsory by law. L Earth (yellow/green) N REPLACING THE INJECTORS (see the injector table in the Instruction) • • • Remove grids (A). Using a socket spanner of the appropriate size unscrew the injector (C), unscrew the injector to be replaced. • Replace it with the injector suitable for the new type of gas. • If you have a multiple crown burner use side spanner to replace the injector (E). Before installing the hob, remember to affix the gas calibration plate supplied with the injectors in such a way that it covers the existing information relating to gas calibration. IMPORTANT: the data relevant to the voltage and power absorption are indicated on the rating plate. ASSEMBLY After having cleaned the perimeter surface, apply the supplied gasket to the hob as shown in the figure. ADJUSTING MINIMUM GAS SETTING OF TAPS To ensure that the minimum setting is correctly adjusted, remove the knob and proceed as follows: • tighten screw to reduce the flame height (-); • loosen screw to increase the flame height (+). The adjustment must be performed with the tap in minimum gas setting position (small flame) . • The primary air of the burners does not need to be adjusted. • 40 Position the hob in the worktop opening made respecting the dimensions indicated in the Instruction. NOTE: the power supply cable must be long enough to permit its upward extraction. To secure the hob, use the brackets (A) provided with it. Fit the brackets into the relevant bores shown by the arrow and fasten them by means of their screws in accordance with the thickness of the worktop (see the following figures). Top 20 mm 20 Top 40 mm At this stage, light up the burners and turn the knobs from max position to minimum position to check flame stability. Upon completion of adjustment, reseal using sealing wax or an equivalent material. REFERENCE TO LOCAL REGULATIONS Top 30 mm 30 60 Top 60 mm Provision for ventilation The room in which the appliance is installed must have an air supply to current B. S. All rooms require a permanent vent in addition to the openable window. If there are other fuel burning appliances in the same room B. S. 5440 - Part 2 should be consulted to determine the air vent requirements. If the appliance is installed in a cellar or basement, it is advisable to provide an air vent of 65 cm, irrespective of the room volume. ADJUSTMENT TO DIFFERENT TYPES OF GAS WARNING This operation must be performed by a qualified technician. Gas Safety Regulations The law requires that all gas appliances are installed by competent persons in accordance with the current gas safety regulations. [. . . ] When replacing the grids, make sure that the panstand area is aligned with the burner. Models equipped with electrical ignition plugs and safety device require thorough cleaning of the plug end in order to ensure correct operation. Check these items frequently, and if necessary, clean them with a damp cloth. Any baked-on food should be removed with a toothpick or needle. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL AKT 923/IXL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual WHIRLPOOL AKT 923/IXL will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag