[. . . ] 33933051GB. fm Page 137 Tuesday, January 18, 2005 3:31 PM
INSTRUCTIONS FOR USE
DUAL SPLIT AIR CONDITIONER WITH GREEN GAS
AND WITH ECO GAS
PREPARATION BEFORE USE SAFETY PRECAUTIONS IDENTIFICATION OF PARTS REMOTE CONTROL OPERATION INSTRUCTIONS MAINTENANCE TROUBLESHOOTING PROTECTION INSTALLATION INSTRUCTIONS ELECTRICAL CONNECTION
GREEN RANGE ECO RANGE
This appliance is marked according to the European directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE). This guideline is the frame of a European-wide validity of return and recycling on Waste Electrical and Electronic Equipment. 137
33933051GB. fm Page 138 Tuesday, January 18, 2005 3:31 PM
PREPARATION BEFORE USE
Before using the air conditioner, be sure to check and preset the following. • Remote Control presetting The remote control is NOT preset as Cooling Only Air Conditioner or Heat Pump by manufacturer. [. . . ] • *The set temperature will rise by max. 1°C if the appliance operates in cooling mode for two hours, then it will remain constant. • The set temperature will decrease by max 3°C is the appliance operates in heating mode for 3 hours, then it will remain constant. COOLING
8 hours timer 1 hour 1 hour Rise by 0. 5°C SET TEMP. START STOP Rise by 0. 5°C
**HEATING
8 hours timer 1 hour SET TEMP. 1 hour Decrease by 1°C Decrease by START Decrease by 1 hour
STOP
*: In cooling mode, if room temperature is 26°C or above, set temperature will not change. **: Heating is NOT available for cooling only air conditioner.
145
33933051GB. fm Page 146 Tuesday, January 18, 2005 3:31 PM
MAINTENANCE
Appliance maintenance
Unplug from the power supply Stop the appliance before unplugging. • To remove the front panel pull it outwards as shown in the figure (a)
Wipe with a soft, dry cloth Use lukewarm water (below 40°C) to clean the appliance when it is very dirty. • Use a dry and soft cloth to clean it. Never use volatile substances such as gasoline or polishing powder to clean the unit. Never sprinkle water on the indoor unit • Danger!Refit and close the front panel • Refit and close the front panel by pushing it downwards as shown in the figure (b).
Clean the air filter
It is advisable to clean the air filter after approx. Stop the appliance and remove the air filter 1. Press the air filter handle gently from the front. Grasp the handle and slide out the filter. Replace the filter in its original position after cleaning If the filter is very dirty, clean it with a solution of lukewarm water and neutral detergent, then dry it in the shade. IMPORTANT: Clean the air filter every two weeks when the air conditioner is operated in a dusty environment.
1 2 3
TROUBLESHOOTING
Trouble
Does not run
Analysis
• • • • • • • • • • • • • Is the protection device or fuse blown?Sometimes it stops working to protect the appliance. Are the intakes and outlets of the air conditioner obstructed. If there is a strong interference (from excessive static electricity discharge, power supply voltage abnormality) presents, operation will be abnormal. In this case, unplug from the power supply and plug in after 2-3 seconds. Changing mode in operation, there may be a delay of 3 minutes. [. . . ] - Secure the power connecting cord on the control board with a cable clamp. - Refit the access door in the original position and tighten the screw. - Use a recognized circuit breaker for 24 K model between the power source and the unit. A disconnecting device to adequately disconnect all supply lines must be fitted.
CAUTION: 1. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL AMB 891/G
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.