Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual WHIRLPOOL AMD 030 - 034. We hope that this WHIRLPOOL AMD 030 - 034 user guide will be useful to you.
Lastmanuals help download the user guide WHIRLPOOL AMD 030 - 034.
Manual abstract: user guide WHIRLPOOL AMD 030 - 034
Detailed instructions for use are in the User's Guide.
[. . . ] а употреба
Návod k použití Návod na použitie Instruc∑iuni de utilizare Инструкции по эксплуатации
501932602028:Layout 1
1-12-2008
16:58
Pagina 2
501932602028:Layout 1
1-12-2008
16:58
Pagina 3
ENGLISH
РУCCКИЙ
Instructions for use
Инcтpyкции по экcплyaтaции
Page 4
Cтpaницa 27
3
501932602028:Layout 1
1-12-2008
16:58
Pagina 4
AMD 030 - 031 - 032 - 033 - 034
INSTRUCTIONS FOR USE
BEFORE USING THE APPLIANCE SAFETY PRECAUTIONS AIR CONDITIONER PRECAUTIONS SAFEGUARDING THE ENVIRONMENT PRODUCT DESCRIPTION CONTROL PANEL DISPLAY INDICATORS DESCRIPTION REMOTE CONTROL FUNCTIONS AND INDICATORS INDICATOR SYMBOLS ON RC DISPLAY STORAGE AND TIPS FOR USING THE RC OPERATING MODE DESCRIPTION AIRFLOW DIRECTION CONTROL MODE AND FUNCTION DESCRIPTIONS MAINTENANCE PROTECTION TROUBLESHOOTING INSTALLATION INSTRUCTIONS INDOOR UNIT INSTALLATION WIRING DIAGRAM OUTDOOR UNIT INSTALLATION
4
Page 5 5 6 6 7 8 9 9 10 11 12 13 16 16 17 18 20 23 25
501932602028:Layout 1
1-12-2008
16:58
Pagina 5
BEFORE USING THE APPLIANCE
To make the most out of your new appliance, please read the user instructions carefully and keep them handy for future consultation. Before using the appliance please follow and set according to the below indications: Remote Control (RC) presetting: Each time the batteries are replaced in the remote control, the RC is pre-set on Heat pump. If the air conditioner that you purchased is a cooling only, then the pre-set on Heat pump will not bring any changes. Auto-Restart presetting Function: To set the auto-restart function, press the Emergency button (ON/OFF) on the indoor unit for at least 5 seconds A buzz sound will signal that the auto-restart function is set and the air conditioner is in standby. [. . . ] Clean the air filter every two weeks if the air conditioner operates in an extremely dusty environment. Unplug from the power supply Turn off the appliance first before disconnecting from power supply and remove the air filter. If the filter is very dirty, clean it with a solution of lukewarm water and neutral detergent. B
PROTECTION
Operating condition The protective device maybe trip and stop the appliance in the cases listed below. Outdoor air temperature is over 24°C HEATING Outdoor air temperature is below -7°C Room temperature is over 27°C Outdoor air temperature is over *43°C COOLING Room temperature is below 21°C DRY Room temperature is below 18°C *For Tropical (T3) Climate condition models, the temperature point is 52°C instead of 43°C. If the air conditioner runs in COOLING or DRY mode with door or window opened for a long time when relative humidity is above 80%, dew may drip down from the outlet. Noise pollution • Install the air conditioner at a place that can bear its weight in order to operate more quietly. 16
501932602028:Layout 1
1-12-2008
17:02
Pagina 17
• Install the outdoor unit at a place where the air discharged and the operation noise would not annoy your neighbours. Do not place any obstacles in front of the air outlet of the outdoor unit lest it increases the noise level. Protection device Wait at least 3 minutes before restarting the unit after operation stops or changing mode during operation. After connecting to power supply and turning on the appliance immediately, a delay of 20 seconds may occur before it starts to operate. If all operation has stopped, press ON/OFF button again to restart. Timer should be set again if it has been cancelled. Features of HEATING mode Preheating 2-5 minutes are necessary to preheat the indoor unit at HEATING operation start. Defrosting (out door unit) In HEATING operation the appliance will defrost (de-ice) automatically to raise efficiency. This procedure usually lasts 2-10 minutes. after defrosting completes , it returns to HEATING mode automatically. Note: Heating is NOT available for cooling only air conditioner models. tROUBLESHOOTING
Trouble Analysis • Is the protection device or fuse blown? Please wait for 3 minutes and start again, protection device may be preventing unit to work. Are the intakes and outlets of the air conditioner blocked? • Is the temperature set properly? [. . . ] If installed on the wall or roof, make sure to fix the supporter well to prevent it from shaking due to serious vibration or strong wind. Outdoor Unit Piping Connection • Remove the valve caps from the 2-way and 3-way valve. Connect the pipes to the 2-way and 3-way valves separately according to the required torque. Outdoor Unit Cable Connection (see previous page) Air purging Air containing moisture remaining in the refrigeration cycle may cause a malfunction on the compressor. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL AMD 030 - 034
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.