[. . . ] INSTALLATION INSTRUCTIONS 30" (76 CM) FREESTANDING ELECTRIC RANGES
Table of Contents
RANGE SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 INSTALLATION REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Tools and Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Location Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Failure to follow these instructions can result in death, fire, or electrical shock.
Electrical Shock Hazard Disconnect power before servicing. Use 8 gauge copper or 6 gauge aluminum wire. Failure to follow these instructions can result in death, fire, or electrical shock.
1. Remove the terminal block cover screws located on the back of the range. Pull cover down and toward you to remove cover from range.
3. Remove plastic tag holding three 10-32 hex nuts from the middle post of the terminal block.
A
B
C
A. Style 1: Power supply cord strain relief
Electrical Connection Options If your home has: 4-wire receptacle (NEMA type 14-50R) And you will be connecting to: A UL listed, 250-volt minimum, 40-amp, range power supply cord Go to Section: 4-wire connection: Power supply cord
Remove the knockout for the power supply cord. Assemble a UL listed strain relief in the opening.
4-wire direct
³/" (1. 0 cm)
A circuit breaker box or fused disconnect
4-wire connection: Direct wire
A
5" (12. 7 cm)
A. UL listed strain relief
Tighten strain relief screw against the power supply cord.
3-wire receptacle (NEMA type 10-50R)
A UL listed, 250-volt minimum, 40-amp, range power supply cord
3-wire connection: Power supply cord
3-wire direct Style 2: Direct wire strain relief
³/" (1. 0 cm)
A circuit breaker box or fused disconnect
3-wire connection: Direct wire
Remove the knockout as needed for the flexible conduit connection. Assemble a UL listed conduit connector in the opening.
3" (7. 6 cm)
4-wire connection: Power Supply Cord
A
Use this method for: New branch-circuit installations (1996 NEC)
Mobile homes Recreational vehicles In an area where local codes prohibit grounding through the neutral
B
1. Part of metal ground strap must be cut out and removed.
A. Concuit
Tighten strain relief screw against the flexible conduit.
A B C
A. Complete installation following instructions for your type of electrical connection: 4-wire (recommended) 3-wire (if 4-wire is not available)
2. Use a Phillips screwdriver to remove the ground-link screw from the back of the range. Save the ground-link screw and the end of the ground-link under the screw.
8
3. Feed the power supply cord through the strain relief on the cord/conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block.
3-wire connection: Power Supply Cord
Use this method only if local codes permit connecting chassis ground conductor to neutral wire of power supply cord. Feed the power supply cord through the strain relief on the cord/conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block.
A B
A B C D
C
A. Use a Phillips screwdriver to connect the green ground wire from the power supply cord to the range with the ground-link screw and ground-link section. Use ³/" nut driver to connect the neutral (white) wire to the center terminal block post with one of the 1032 hex nuts.
A. Power supply cord wires - large opening
2. [. . . ] Slowly push the storage drawer into the range until the drawer side rails engage with the gap in the drawer glides.
Complete Installation
1. If there is an extra part, go back through the steps to see which step was skipped. Dispose of/recycle all packaging materials. Use a mild solution of liquid household cleaner and warm water to remove waxy residue caused by shipping material. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL GFE471LVS
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual WHIRLPOOL GFE471LVS will begin.