[. . . ] Ice Maker
PRODUCT MODEL NUMBERS GI15NDXT GI15NFLT GI15NFRT CABINET OPENING DIMENSIONS
Electrical: 115-Volt, 60-Hz, AC-only 15- or 20-amp fused, grounded electrical supply is required. It is recommended that a separate circuit serving only your refrigerator drawers be provided. [. . . ] s Installation of the ice maker requires a cold water supply inlet of 1/4" (6. 35 mm) OD soft copper tubing with a shutoff valve and either a gravitydrain system or condensate pump to carry the water to an existing drain. s Choose a well ventilated area with temperatures above 55°F (13°C) and below 110°F (43°C). Best results are obtained between 70°F (21°C) and 90°F (32°C).
11¹/ " (29. 2 cm) 34" (86. 4 cm) Min. 34¹/ " (87. 6 cm) Max.
A
28¹/ " (72. 4 cm)
3¹/ " 9" (8. 9 cm) (22. 9 cm)
24" (60. 1 cm)
B
15" (38. 1 cm)
A. Recommended location for electrical and plumbing fixtures. Floor level
s Be sure the power supply cord is not pinched between the ice maker and
the cabinet.
s Be sure the water supply line is not pinched between the ice maker and the
cabinet.
s Be sure the drain line (on some models) is not pinched between the ice
maker and the cabinet.
s Choose a location where the floor is even. It is important for the ice maker
to be level in order to work properly. DRAIN REQUIREMENTS Drain: Either a gravity-drain system or condensate pump to carry water to an existing drain. s Drain lines must have a minimum of 5/8" (15. 88 mm) inside diameter. s Drain lines must have a 1" drop per 48" (2. 54 cm drop per 122 cm) of run or 1/4" drop per 12" (6. 35 mm per 30. 48 cm) of run and must not have low points where water can settle. [. . . ] For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL GI15NFLT
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.