Detailed instructions for use are in the User's Guide.
[. . . ] NUTID
HGA3K
GB DE FR NL
FR
BE
FR ENGLISH
BE DEUTSCH FRANÇAIS NEDERLANDS
4 17 31 51
Language, Sprache, Langue, Taal Country, Land, Pays, Land
ENGLISH
4
Safety information Product description Daily use Helpful hints and tips Maintenance and cleaning What to do if
Table of contents
Your safety and the safety of others are very important. This manual and the appliance itself provide important safety messages, to be read and observed at all times. This is the safety alert symbol, pertaining to safety, which alerts users to potential hazards to themselves and others. All safety messages will follow the safety alert symbol and either the terms: DANGER Indicates a hazardous situation which, if not avoided, will cause serious injury. [. . . ] Turn the hob on again to check if correct operation has been restored. If the problem persists, contact the Aftersales Service. Give the following information: • type of fault; • hob model; • service number (i. The number after the word SERVICE on the dataplate under the hob and on the warranty certificate);
• your full address; • your telephone number. If any repairs are required, contact an authorised service centre, indicated in the warranty. In the unlikely event that an operation or repair is carried out by an unauthorised technician, always request certification of the work carried out and insist on the use of original spare parts. Failure to comply with these instructions may compromise the safety and quality of the product. ENGLISH
9
Injector table
Category II2E+3+ Type of gas used Type of burner Injector Nominal Nominal marking heating consumcapacity ption kW Reduced heat capacity kW BE NATURAL GAS (Methane) G20 NATURAL GAS (Methane) G25 LIQUEFIED PETROLEUM GAS (Butane) G30 LIQUEFIED PETROLEUM GAS (Propane) G31 Type of gas used wok semi-rapid auxiliary wok semi-rapid auxiliary wok semi-rapid auxiliary wok semi-rapid auxiliary 140 97 74 B 140 97 74 B 93 65 50 93 65 50 3, 50 1, 65 1, 00 3, 50 1, 65 1, 00 3, 50 1, 65 1, 00 3, 50 1, 65 1, 00 333 l/h 157 l/h 95 l/h 388 l/h 183 l/h 1 1 l/h 1 254 g/h 120 g/h 73 g/h 250 g/h 1 g/h 18 71 g/h FR Gas pressure (mbar)
min. 17 20 25
1, 55 1, 55 0, 35 0, 35 0, 40 0, 30 1, 55 0, 35 0, 30 1, 55 0, 35 0, 30 1, 55 0, 35 0, 30
20
25
30
20
28 30
35
25
37
45
Model configuration
Nominal heating Total nominal capacity kW consumption
Air necessary (m3) for combustion 1 m3 of gas 9, 52 8, 187 30, 94 23, 80
G20 20 mbar G25 25 mbar G30 28-30 mbar G31 37 mbar
3 gas 3 gas 3 gas 3 gas
6, 15 6, 15 6, 15 6, 15
585 l/h 682 l/h 447 g/h 439 g/h
Electric Power: 230 V ~ 50 Hz
ENGLISH
10
Technical data
Dimensions Width (mm) Height (mm) Length (mm) Voltage (V) The technical information are situated in the rating plate on the bottom side of the appliance and in the energy label. 770 47 350 230
After unpacking the hob, make sure that it has not been damaged during transport. In the event of problems, contact the dealer or your nearest After-sales Service. Technical information for the installer -- This product can be embedded in a worktop 20 to 60 mm thick. -- If there is no oven beneath the hob, insert a separator panel that has a surface at least equal to the opening in the work surface. This panel must be positioned at a maximum distance of 150 mm below the upper surface of the work surface but, in no case less than 20 mm from the bottom of the hob. -- Before installation, make sure that: -- the local gas delivery conditions (nature and pressure) are compatible with the settings of the hob (see the rating plate and injector table); -- the outer surfaces of the furniture or appliances adjacent to the hob are heat
Installation
resistant according to local regulations; -- This appliance is not connected to a fume exhaust device. It shall be installed in accordance with current installation regulations. Particular attention shall be given to the relevant requirement regarding ventilation. -- Combustion products are discharged outdoors through specific hoods or wall and/or window mounted electrical fans. gas connection This operation must be performed by a qualified technician. The gas supply system must comply with local regulations to the relavant gas standard. -- You can find specific local regulations for some countries in the paragraph -- “Reference to Local Regulations”. If no information concerning your Country is given, please ask details to a qualified technician. [. . . ] Repairs caused by installation which is faulty or not according to specification. The use of the appliance in a non-domestic environment i. If a customer transports the product to his home or
ENGLISH
16
another address, IKEA is not liable for any damage that may occur during transport. However, if IKEA delivers the product to the customer’s delivery address, then damage to the product that occurs during this delivery will be covered by IKEA. [. . . ]