Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual WHIRLPOOL TGZ 3405-1 IN. We hope that this WHIRLPOOL TGZ 3405-1 IN user guide will be useful to you.
Lastmanuals help download the user guide WHIRLPOOL TGZ 3405-1 IN.
Manual abstract: user guide WHIRLPOOL TGZ 3405-1 INPROGRAM CHART
Detailed instructions for use are in the User's Guide.
[. . . ] The burner might go out when the knob is released. This means that the thermocouple has not warmed up enough. In this case, repeat the operations described above.
• -
NOTE: In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct distance. [. . . ] INJECTOR TABLE
Type of gas used Type of burner Injector marking ultra-rapid semi-rapid auxiliary ultra-rapid semi-rapid auxiliary ultra-rapid semi-rapid auxiliary 136 95 78 151 104 82 83 60 46 Rated thermal Rated flow rate kW consumption 3. 50 1. 65 1. 00 3. 50 1. 65 1. 00 3. 50 1. 65 1. 00 333 l/h 157 l/h 95 l/h 389 l/h 183 l/h 111 l/h 254 g/h 120 g/h 73 g/h
CATEGORY II2H3B/P (AT) II2ELL3B/P (DE)
Reduced heat capacity kW 1. 50 0. 35 0. 30 1. 50 0. 35 0. 30 1. 95 0. 45 0. 35 Gas pressure (mbar) min. 25
PRATICAL ADVICE FOR USING THE BURNERS
For better burner performance, please stick to the following rules: Use pots and pans that fit the burners (see table on the right). Use the correct amount of water for cooking foods and keep the pot covered. Burner ultra-rapid semi-rapid auxiliary Pot Ø
from 24 to 26 cm from 16 to 22 cm from 8 to 14 cm
NATURAL GAS
(Methane) *NATURAL GAS (Methane) G20
G25
18
20
25
LIQUID PETROLEUM GAS
(Butane) (Propane) Type of gas used G20 20 mbar *G25 20 mbar G30/G31 50 mbar G30 G31
42. 5
50
57. 5
Configuration model 4 burners 4 burners 4 burners
Rated thermal flow rate kW 7. 80 7. 80 7. 80
Total rated consumption 742 l/h 866 l/h 567 g/h
Air necessary (m3) for the combustion of 1 m3 of gas 9. 52 8. 187 30. 94
* Not available for Austria ELECTRIC SUPPLY: 230 V - 50 Hz
5019 419 62007
To get full satisfaction from the hob, please read these instructions carefully and keep them for future consultation.
PRECAUTIONS AND GENERAL ADVICE
To get full satisfaction from your hob, please read these instructions carefully and keep them for future consultation
NOTES:
• • • • • • •
These instructions are only valid for those Countries where the destination abbreviations are mentioned on the product description sheet and on the hob. Keep the packaging material (plastic bags, polystyrene parts, etc. ) out of the reach of children, as they are potentially dangerous. Check whether the hob has been damaged during transport and remove any protective film from the appliance parts. This hob (Class 3) is designed solely for household use for cooking food. Any other use (such as heating rooms) is to be considered improper and, as a consequence, dangerous. Ensure that the installation and gas/electrical connections are performed by a qualified technician in compliance with current local safety regulations. The manufacturer declines all liability if another brand oven is installed beneath the hob. Before installation, make sure that: the local gas delivery conditions (nature and pressure) are compatible with the settings of the hob (see the rating plate and injector table). The outer surfaces of the furniture or appliances adjacent to the hob are heat resistant according to local regulations. Combustion products are discharged outdoors through specific hoods or wall and/or window mounted electrical fans. Continuous natural air circulation is ensured through a clear opening in a wall of at least 100 cm2. This wall opening must be: permanent and in a wall to the outside of the room to be vented; made in such a way that it cannot be obstructed from the inside or outside (not even accidentally); protected by plastic grids, metallic mesh, etc. , taking care not to reduce the air vent effective area mentioned above; located near floor level and positioned so as not to interfere with the operation of the exhaust system.
REFERENCE TO LOCAL REGULATIONS DE It is law that all gas appliances are installed and connected to the gas supply by authorised technicians. The installation must be performed in accordance with the TRGI (technical regulations for gas connection) and/or TRF (technical regulations for liquid gas). Failure to install appliances correctly could lead to prosecution. It is in your own interest, and that of safety, to ensure that the law is complied with. [. . . ] It is in your own interest, and that of safety, to ensure that the law is complied with. AT Ensure that the installation and gas connections are performed by a qualified technician, following the manufacturer’s instructions and in compliance with current local safety regulations. Packaging
• -
a) The packaging material is entirely recyclable, and is marked with the recycling symbol , which identifies it as a type of b) material that must be sent to local waste-disposal centres. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL TGZ 3405-1 IN
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual WHIRLPOOL TGZ 3405-1 IN will begin.