If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual WHIRLPOOL WFG540H0AH. We hope that this WHIRLPOOL WFG540H0AH user guide will be useful to you.
Lastmanuals help download the user guide WHIRLPOOL WFG540H0AH.
Manual abstract: user guide WHIRLPOOL WFG540H0AHUSE & CARE GUIDE
Detailed instructions for use are in the User's Guide.
[. . . ] 2 Electrical Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 INSTALLATION INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Unpack Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Install Anti-Tip Bracket. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Electrical Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] **If connecting to a 50-amp circuit, use a 50-amp rated cord with kit. For 50-amp rated cord kits, use kits that specify use with a nominal 1³/" (34. 9 mm) diameter connection opening. A time-delay fuse or circuit breaker is recommended.
4-wire receptacle (14-50R)
The range can be connected directly to the fused disconnect (or circuit breaker box) through flexible or nonmetallic sheathed, copper or aluminum cable. See "Electrical Connection. " Allow 2 to 3 ft (61. 0 cm to 91. 4 cm) of slack in the line so that the range can be moved if servicing is ever necessary. A UL listed conduit connector must be provided at each end of the power supply cable (at the range and at the junction box). Wire sizes and connections must conform with the rating of the range. The wiring diagram is located on the back of the range or inside the storage drawer in a clear plastic bag.
The minimum conductor sized for the copper 4-wire power cord are: 40-amp circuit 2 No. -8 conductors 1 No. -10 white neutral 1 No. -8 green grounding
If connecting to a 3-wire system:
Local codes may permit the use of a UL listed, 3-wire, 250-volt, 40- or 50-amp range power supply cord (pigtail). This cord contains 3 copper conductors with ring terminals or open-end spade terminals with upturned ends, terminating in a NEMA Type 10-50P plug on the supply end. Connectors on the appliance end must be provided at the point the power supply cord enters the appliance. This uses a 3-wire receptacle of NEMA Type 10-50R.
3-wire receptacle (10-50R)
INSTALLATION INSTRUCTIONS
Unpack Range
WARNING
Excessive Weight Hazard Use two or more people to move and install range. Failure to do so can result in back or other injury.
2. Bend the ground-link away from the range so that it does not contact the range.
B
A. Strain relief
Tighten strain relief screw against the flexible conduit.
C B A
A. Complete installation following instructions for your type of electrical connection: 4-wire (recommended) 3-wire (if 4-wire is not available) Electrical Connection Options If your home has: 4-wire receptacle (NEMA type 14-50R) And you will be connecting to: A UL listed, 250-volt minimum, 40-amp, range power supply cord Go to Section:
2. Connect the green ground wire from the power supply cord to the range using the ground-link screw and cup washer. The ground wire must be attached first and must not contact any other terminal. Use a ¼" nut driver to remove the hex washer head screws from the terminal blocks. Connect the neutral (center) wire to the center terminal connector using one of the hex washer head screws. Securely tighten screw for proper electrical connection.
E
4-wire connection: Power supply cord
D C B G H F
4-wire direct
5" (12. 7 cm)
A fused disconnect or circuit breaker box A UL listed, 250-volt minimum, 40-amp, range power supply cord
4-wire connection: Direct wire
A I
A. UL listed strain relief and 40- or 50-amp range power supply cord
3-wire receptacle (NEMA type 10-50R)
3-wire connection: Power supply cord
3-wire direct
1" (2. 5 cm)
A fused disconnect or circuit breaker box
3-wire connection: Direct wire
5. Connect the other 2 wires (lines 1 and 2) to the outer aluminum terminal blocks. Securely tighten screws for proper electrical connection. [. . . ] On Ranges Equipped with Storage Drawers: Use ³/" drive ratchet and channel lock pliers to adjust leveling legs up or down until range is level. Check that rear leveling leg is engaged in anti-tip bracket. On Ranges Equipped with Warming Drawers: Use channel lock pliers to adjust leveling legs up or down until range is level. Check that rear leveling leg is engaged in anti-tip bracket. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL WFG540H0AH
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.