Manual abstract: user guide WHIRLPOOL WGD4995EWDIMENSION GUIDE
Detailed instructions for use are in the User's Guide.
[. . . ] 29" and 27" Wide Gas Dryers
PRODUCT MODEL NUMBERS WGD4890B, WGD4995E, WGD4890B
29" Wide Models – Dryer Dimensions
22 / " (578 mm)
3 4
27" Wide Models – Dryer Dimensions
29" (737 mm) 223/4" (578 mm) 291/2" (749 mm) 27" (686 mm)
27 / "* (705 mm) 26"** (660 mm)
3 4
411/2" (1054 mm)
43" (1092 mm)
A
13 / " (349 mm)
3 4
11/2" (38 mm) 29" (737 mm) 133/4" (349 mm) 291/2" (749 mm)
B
A
11/2" (38 mm) 27" (686 mm)
27 / "* (705 mm) 26"** (660 mm)
3 4
411/2" (1054 mm)
43" (1092 mm)
1/2" (13 mm)
* 6. 5 or 7. 0 cu. [. . . ] Pipe-joint compounds resistant to the action of L. P. An individual manual shutoff valve must be installed within 6 ft (1. 8 m) of the dryer in accordance with the National Fuel Gas Code ANSI Z223. 1.
ELECTRICAL REQUIREMENTS
A 120-volt, 60 Hz, AC-only, 15 or 20 amp fused electrical supply is required. A time-delay fuse or circuit breaker and a separate circuit are recommended.
WATER (STEAM MODELS ONLY) REQUIREMENTS
The dryer must be connected to the cold water faucet using new inlet hoses. Damage to the coupling can result.
VENTING REQUIREMENTS
Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm)
diameter vent is required. Rigid or flexible metal exhaust vent must be used. Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust.
The “Vent System Chart” provides venting requirements that will help achieve best drying performance.
Vent System Chart
Number of 90° turns or elbows 0 1 2 Type of vent Rigid metal Rigid metal Rigid metal Rigid metal Rigid metal Box/louvered hoods 64 ft. (6. 4 m)
Exhaust hoods: Recommended Styles:
Louvered Hood
Box Hood
3 4
Acceptable Style:
NOTE: Side and bottom exhaust installations for 27" wide models have a 90º turn inside the dryer. [. . . ] Specifications subject to change without notice. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL WGD4995EW
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.