User manual WHIRLPOOL WGD49STBW DIMENSION GUIDE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual WHIRLPOOL WGD49STBW. We hope that this WHIRLPOOL WGD49STBW user guide will be useful to you.

Lastmanuals help download the user guide WHIRLPOOL WGD49STBW.


Mode d'emploi WHIRLPOOL WGD49STBW
Download

You may also download the following manuals related to this product:

   WHIRLPOOL WGD49STBW USE & CARE GUIDE (4524 ko)
   WHIRLPOOL WGD49STBW INSTRUCTION SHEET (795 ko)
   WHIRLPOOL WGD49STBW INSTALLATION GUIDE (11581 ko)
   WHIRLPOOL WGD49STBW WARRANTY INFORMATION (101 ko)
   WHIRLPOOL WGD49STBW VENTILATION SPECIFICATION (1518 ko)

Manual abstract: user guide WHIRLPOOL WGD49STBWDIMENSION GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] Gas Dryer PRODUCT MODEL NUMBERS WGD49STB 29" Wide Models Dryer Dimensions Front View Side View 29" (737 mm) 223/4" (578 mm) 273/4" (705 mm) 133/4" (349 mm) 273/4" (705 mm) 433/8" (1102 mm) 1/2" (13 mm) A A. Wide opening hamper door Back View B NOTE: Leveling legs should be 1/2" (13 mm) (to match height of 3. 6 cu. [. . . ] ■■ Additional clearances might be required for wall, door, and floor moldings. ■■ Additional spacing of 1" (25 mm) on all sides of the dryer is recommended to reduce noise transfer. ■■ For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable. ■■ Companion appliance spacing should also be considered. INSTALLATION REQUIREMENTS GAS SUPPLY REQUIREMENTS Gas supply: This dryer is equipped for use with Natural gas. When rigid pipe is used it should be 1/2" IPS. When acceptable to the gas supplier and local codes, 3/8" approved tubing may be used for lengths under 20 ft (6. 1 m). For lengths over 20 ft (6. 1 m), larger tubing should be used. Pipe-joint compounds resistant to the action of L. P. An individual manual shutoff valve must be installed within 6 ft (1. 8 m) of the dryer in accordance with the National Fuel Gas Code ANSI Z223. 1. ELECTRICAL REQUIREMENTS A 120-volt, 60 Hz, AC-only, 15 or 20 amp fused electrical supply is required. A time-delay fuse or circuit breaker and a separate circuit are recommended. WATER (STEAM MODELS ONLY) REQUIREMENTS The dryer must be connected to the cold water faucet using new inlet hoses. Damage to the coupling can result. VENTING REQUIREMENTS Exhaust venting: Exhaust your dryer to the outside. [. . . ] For complete details, see Installation Instructions packed with product. Specifications subject to change without notice. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL WGD49STBW

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual WHIRLPOOL WGD49STBW will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag