[. . . ] The total length of flexible metal vent should not exceed 7-3/4 ft. Exhaust outlet hood must be at least 12" (30. 5 cm) from the ground or any object that may be in the path of the exhaust. Gas supply: This dryer is equipped for use with Natural gas. [. . . ] No attempt shall be made to convert the appliance from the gas specified on the model/serial rating plate for use with a different gas without consulting your gas company. Must include 1/8" NPT minimum plugged tapping accessible for test gauge connection, immediately upstream of the gas connection to the dryer. 3/8" approved aluminum or copper tubing is acceptable for lengths under 20 ft (6. 1 m) if local codes and gas supplier permit. If you are using Natural gas, do not use copper tubing. Lengths over 20 ft (6. 1 m) should use larger tubing and a different size adapter fitting. If your dryer has been converted to use LP gas, 3/8" LP compatible copper tubing can be used. If the total length of the supply line is more than 20 ft (6. 1 m), use larger pipe. NOTE: Pipe joint compounds that resist the action of LP gas must be used. For cabinet installation, with a door, minimum ventilation openings in the top of the cabinet are required. A* A* B* B* C* D** C* E F* G H I Steam (Electric or Gas) 7" (178 mm) 7" (178 mm) 9" (229 mm) 5" (127 mm) 32 /16" (686 mm)
9
Non-Steam (Electric or Gas) 7" (178 mm) 7" (178 mm) 9" (229 mm) 5" (127 mm) 31 1/2" (800 mm) 1" (25 mm) 1" (25 mm) 27" (686 mm) 1" (25 mm)
1" (25 mm) 1" (25 mm) 27" (686 mm) 1" (25 mm)
D**
E
F* G
H
I
*Required spacing **For side or bottom venting, 0" (0 mm) spacing is allowed.
Page 2 of 3 Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice. W10224610 11-09-08
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
®
Gas Dryer
PRODUCT MODEL NUMBERS WGD9750W WGD9300V WGD9400S WGD9400V WGD9500T WGD9600T
RECOMMENDED INSTALLATION SPACING FOR RECESSED OR CLOSET INSTALLATION, WITH STACKED WASHER AND DRYER Dimensions shown are for recommended spacing.
48 in. 2 * (310 cm2) 3"* (76 mm) 6"* (152 mm)
Steam (Electric or Gas) A*
76" (1930 mm)
Non-Steam (Electric or Gas) 5" (127 mm)
5 ½" (140 mm)
*Required spacing NOTE: Some models are not recommended for stacked recessed or closet installation.
3"* (76 mm) 24 in. 2 * (155 cm2) 1"* (25 mm) A* 1" (25 mm) 27" (686 mm) 1" (25 mm)
* Required spacing
CUSTOM UNDERCOUNTER INSTALLATION DRYER ONLY
Dimensions shown are for minimum spacing.
A
Steam (Electric or Gas) A B B C* C* D E* D E*
0" (0 mm) 38" (9652 mm) 1" (25 mm) 27" (686 mm) 1" (25 mm)
Non-Steam (Electric or Gas)
0" (0 mm) 38" (9652 mm) 1" (25 mm) 27" (686 mm) 1" (25 mm)
* Required spacing
*Required spacing NOTE: Some models are not recommended for undercounter installation. EXHAUST VENTING A and B: Recommended hood styles. NOTE: Side and bottom exhaust installations have a 90º turn inside the dryer. To determine maximum exhaust length, add one 90º turn to the chart.
B
4" (102 mm)
C
Number 90º elbows 0 1
2½" (64 mm)
Type of vent Rigid metal Rigid metal Rigid metal Rigid metal Rigid metal
Box /louvered hoods 64 ft (20 m) 54 ft (16. 5 m) 44 ft (13. 4 m) 35 ft (10. 7 m) 27 ft (8. 2 m)
Angled hoods 58 ft (17. 7 m) 48 ft (14. 6 m) 38 ft (11. 6 m) 29 ft (8. 8 m) 21 ft (6. 4 m)
A
4" (102 mm) 4" (102 mm)
2 3 4
A. [. . . ] To determine maximum exhaust length, add one 90º turn to the chart.
B
4" (102 mm)
C
Number 90º elbows 0 1
2½" (64 mm)
Type of vent Rigid metal Rigid metal Rigid metal Rigid metal Rigid metal
Box /louvered hoods 64 ft (20 m) 54 ft (16. 5 m) 44 ft (13. 4 m) 35 ft (10. 7 m) 27 ft (8. 2 m)
Angled hoods 58 ft (17. 7 m) 48 ft (14. 6 m) 38 ft (11. 6 m) 29 ft (8. 8 m) 21 ft (6. 4 m)
A
4" (102 mm) 4" (102 mm)
2 3 4
A. Angled hood style
Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL WGD9750W
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.