User manual WHIRLPOOL WGG555S0BW DIMENSION GUIDE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual WHIRLPOOL WGG555S0BW. We hope that this WHIRLPOOL WGG555S0BW user guide will be useful to you.

Lastmanuals help download the user guide WHIRLPOOL WGG555S0BW.


Mode d'emploi WHIRLPOOL WGG555S0BW
Download

You may also download the following manuals related to this product:

   WHIRLPOOL WGG555S0BW USE & CARE GUIDE (680 ko)
   WHIRLPOOL WGG555S0BW INSTALLATION GUIDE (2849 ko)
   WHIRLPOOL WGG555S0BW WARRANTY INFORMATION (70 ko)

Manual abstract: user guide WHIRLPOOL WGG555S0BWDIMENSION GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] 3 INSTALLATION INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Unpack Range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Install Anti-Tip Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Electrical Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] When a 4-wire receptacle of NEMA Type 14-50R is used, a matching UL listed, 4-wire, 250-volt, 40- or 50-amp, range power supply cord (pigtail) must be used. This cord contains 4 copper conductors with ring terminals or open-end spade terminals with upturned ends, terminating in a NEMA Type 14-50R plug on the supply end. The fourth (grounding) conductor must be identified by a green or green/yellow cover and the neutral conductor by a white cover. Cord should be Type SRD or SRDT with a UL listed strain relief and be at least 4 ft (1. 22 m) long. The minimum conductor sized for the copper 4-wire power cord are: 40-amp circuit 2 No. -8 conductors 1 No. -10 white neutral 1 No. -8 green grounding If connecting to a 3-wire system: Local codes may permit the use of a UL listed, 3-wire, 250-volt, 40- or 50-amp range power supply cord (pigtail). This cord contains 3 copper conductors with ring terminals or openend spade terminals with upturned ends, terminating in a NEMA Type 10-50P plug on the supply end. Connectors on the appliance end must be provided at the point the power supply cord enters the appliance. This uses a 3-wire receptacle of NEMA Type 10-50R. 3-wire receptacle (10-50R) 4-wire receptacle (14-50R) INSTALLATION INSTRUCTIONS Unpack Range WARNING Excessive Weight Hazard Use two or more people to move and install range. Failure to do so can result in back or other injury. 1. Remove shipping materials, tape and protective film from range. Remove oven racks and parts package from inside oven. Do not remove the shipping base at this time. 3. Use 8 gauge copper or 6 gauge aluminum wire. Failure to follow these instructions can result in death, fire, or electrical shock. 1. Remove the terminal block cover screws located on the back of the range. Pull cover down and toward you to remove cover from range. Electrical Connection Options If your home has: 4-wire receptacle (NEMA type 14-50R) And you will be connecting to: A UL listed, 250-volt minimum, 40-amp, range power supply cord A fused disconnect or circuit breaker box A UL listed, 250-volt minimum, 40-amp, range power supply cord A fused disconnect or circuit breaker box Go to Section: 4-wire connection: Power supply cord A 4-wire direct 4-wire connection: Direct wire B 5" (12. 7 cm) 3-wire receptacle (NEMA type 10-50R) 3-wire connection: Power supply cord C A. Complete electrical connection according to your type electrical supply (4-wire or 3-wire electrical connection). 5. Connect the other 2 wires (lines 1 and 2) to the outer aluminum terminal blocks. Securely tighten screws for proper electrical connection. Plug in range or reconnect power. 4-wire connection: Power supply cord Use this method for: s New branch-circuit installations (1996 NEC) s s s 3-wire connection: Power supply cord Use this method only if local codes permit connecting cabinetground conductor to neutral wire of power supply cord. Use a ¼" nut driver and remove the hex washer head screws from the aluminum terminal blocks. Mobile homes Recreational vehicles In an area where local codes prohibit grounding through the neutral 1. Remove the ground-link screw from the range frame. Save the ground link screw and cup washer. [. . . ] Any method of securing the range is adequate as long as it conforms to the standards in the "Location Requirements" section. 2. Insert the other 2 wires (lines 1 and 2) under the other 2 screw clamps. B A A. Securely tighten the hex washer head screws to 35 in. -lbs minimum torque to make a proper electrical connection. Tighten the locking ring of the conduit connector. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL WGG555S0BW

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual WHIRLPOOL WGG555S0BW will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag