User manual WHIRLPOOL WRF540CWBM WARRANTY INFORMATION
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual WHIRLPOOL WRF540CWBM. We hope that this WHIRLPOOL WRF540CWBM user guide will be useful to you.
Lastmanuals help download the user guide WHIRLPOOL WRF540CWBM.
You may also download the following manuals related to this product:
WHIRLPOOL WRF540CWBM ENERGY GUIDE (118 ko)
WHIRLPOOL WRF540CWBM DIMENSION GUIDE (156 ko)
WHIRLPOOL WRF540CWBM USE & CARE GUIDE (1539 ko)
Manual abstract: user guide WHIRLPOOL WRF540CWBMWARRANTY INFORMATION
Detailed instructions for use are in the User's Guide.
[. . . ] START UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . COMPONENT DESCRIPTION ELECTRICAL SEQUENCE: OPERATION: Water
COMPONENT DESCRIPTION: Control Box
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OPERATION: Refrigeration . SANITIZING AND CLEANING MAINTENANCE: Air Cooled SERVICE DIAGNOSIS: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MAINTENANCE AND CLEANING
MAINTENANCE AND CLEANING: Auger
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
REMOVAL AND REPLACEMENT: Water Reservoir & Bin Controls REMOVAL AND REPLACEMENT: Auger
REMOVAL AND REPLACEMENT: Bearing And Breaker . [. . . ] · unscrewing the auger stud
Inspect the assembly, looking for wear.
ICE LEVEL SENSORS: SLIDE TO REMOVE
1. The bin control uses devices that sense light, therefore they must be kept clean enough so that they can ``see''. At least twice a year, remove the bin control sensors from the base of the ice chute, and wipe the inside clean, as illustrated. The ice machine senses water level by a probe located in the water reservoir. At least twice a year, the probe should be removed from the reservoir, and the tip wiped clean of mineral build-up.
PULL UP TO REMOVE PROBE
CLEAN THE LIGHT SENSORS RESERVOIR
See Removal and Replacement to replace bearing or seals. Check and tighten all bolts and screws.
CLEAN THE WATER LEVEL PROBE
ICE SWEEP
/////////////////////////////////////////// CAUTION: THE TIP IS MADE OF GLASS //////////////////////////////////////////
3. The bearing in the breaker should also be checked at least two times per year .
BREAKER COVER
January 1995 Page 17
NME950 & WRF540CWBM
MAINTENANCE: Air Cooled
Electrical shock hazard. Electrical shock can cause personal injury. Disconnect power before beginning to service components.
5. Clean the air cooled condenser.
The air flow on this model is from front to back, so the inside of the machine will have to be available to clean the air cooled condenser. Use a vacuum cleaner or coil cleaner if needed. Check water supply, filter, strainer, float valve. Check/clean ice level sensors.
Unit off due to ice level sensors (photo-electric eyes) blocked. Unit off due to scale on water level sensor. Unit off due to high pressure control open. Auger motor does not turn.
Clean water level sensor. Check for water interruption (water cooled) or fan motor failure (air cooled). Check for a restricted system Check/replace centrifugal switch. Check, replace board Check, replace sensor Check/replace contactor
Low pressure control open
No ice, auger motor is turning
Check start capacitor. Check start relay Check compressor windings Circuit board compressor relay Check, replace board will not close. High discharge pressure Clean the air filter and because of a dirty condenser condenser. Low capacity because the Clean the water system auger and evaporator are coated with mineral scale Low suction pressure due to Locate leak. [. . . ] When the proper charge is indicated on the scale, shut off the manifold valve(s). Shut off the valve on the refrigerant drum. Re-open the manifold valves until all liquid has flowed out of the hoses. Shut the low side access valve on the ice machine. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL WRF540CWBM
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual WHIRLPOOL WRF540CWBM will begin.