Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual WHISTLER 1675. We hope that this WHISTLER 1675 user guide will be useful to you.
Lastmanuals help download the user guide WHISTLER 1675.
Detailed instructions for use are in the User's Guide.
[. . . ] OWNER'S MANUAL
1675
LASER/RADAR DETECTOR
TM
If you have questions concerning the operation of this Whistler product please call consumer relations:
1-800-531-0004
Hours: Monday - Friday 8:00 am - 5:00 pm CST
Please keep the receipt in a safe place. If the unit is returned without a dated proof of purchase an out of warranty service charge applies. Note: Your warranty period begins at the time of purchase. The warranty is validated only by return of the Warranty Validation card. [. . . ] Display reads:
HIGHWAY
In City Mode, weak speed/safety radar signals give an initial alarm of two beeps, and then remain quiet unless the signal becomes very strong. When the signal strength increases, two additional beeps are provided. In City 1 Mode, only the X band sensitivity is lowered. CAUTION: When selecting this mode, some towns/small cities may still be using X band radar. To enter:
Press : (Quiet) For 2 seconds *Display COMBO To Change, Reads: or Option: Press Combo=Radar & Compass Radar=No Compass Compass=No Radar Tone 1, 2, or 3 (3 different X, K, Ka patterns) X, K, Ka Audio tones 1 beep during Power Up Turns VG-2 On Turns VG-2 Off Turns Safety Radar On Turns Safety Radar Off Battery Saver On Battery Saver Off
2nd time
TONE 3
= YES = NO = ON = OFF = ON = OFF = ON = OFF
3rd time
TEST YES
4th time 5th time
VG2 OFF SAFETY ON B SVR ON
6th time
= ON = OFF
*Factory settings. Press anytime to exit.
16
OPERATION
Teach/Tutorial Mode Provides simulated alerts for each type of signal. · Press City and (Quiet) simultaneously and release. Display reads:
TEACH
Quiet mode can also be accessed while Teach/Tutorial mode is engaged. · Press (Power) to exit.
17
OPERATION
Vehicle Battery Saver Mode The Vehicle Battery Saver Mode automatically shuts off your detector within 3 hours if you forget to turn it off. The timer is reset if the detector is turned off, unplugged or any button is pressed before the 3 hours have expired. The detector will alert you with an audible and visual warning before it shuts off. Display reads:
PWR OFF
During this warning you can reset the unit by pressing any button. If the unit has automatically turned itself off, press the (Power) button to turn the unit back on. You can manually engage the Vehicle Battery Saver Mode by pressing and holding the City button until one beep is heard. Refer to "Option Select Mode" for instructions for deactivating battery saver mode feature.
18
RADAR ALERTS
Speed Radar Audio/Visual Alerts When X, K or Ka is detected the band ID and signal strength is displayed. The audio alert is continuous and has a geiger counter-like pattern. The faster the beep the closer or stronger the radar source. Example:
Ka Band Detected
Display
Ka
9
Digits ramp 1-9
1 = weak signal, 9 = strong signal
Pulse Protection® When a pulse type signal (instant on strong signal) is detected an urgent 3 second audio warning is sounded and the display reads:
PULSE
After 3 seconds standard alert pattern continues.
19
SAFETY RADAR ALERTS
In communities where transmitters are located, the Safety Warning System displays over 60 text messages. When Safety Radar is detected the audio alert is geiger counterlike. Safety Warning System Text Example: Poor Road Surface:
CAUTION POOR ROAD SURFACE
Note: Not all areas have Safety Warning System transmitters.
20
LASER/VG-2 ALERTS
Laser Audio/Visual Alerts When a laser signal is detected the word "Laser" and signal strength is displayed, the audio alert is continuous for a minimum of 3 seconds. Example:
LASER
The more "|||" the closer the laser source.
VG-2 Audio/Visual Alerts
Note: You must turn this feature on in option select mode before it will detect VG-2.
When a VG-2 signal is detected, the detector "hides" its own radiated signal and becomes undetectable by the VG-2.
VG2 VG2
Text message confirms detection of VG-2.
Every 30 seconds, the detector checks for a VG-2 signal. If a VG-2 signal is still present, the unit continues to hide and repeats the VG-2 alert. [. . . ] For reference, please write your unit's serial number in the following space: s/n __________________. Units without serial numbers are not covered under warranty. IMPORTANT: To validate that your unit is within the warranty period, make sure you keep a copy of your dated proof of purchase and return the Warranty Validation card.
29
WARRANTY INFORMATION
Service Out Of Warranty Units will be repaired at "out of warranty" service rates when: · The unit's original warranty has expired. · Dated proof of purchase is not supplied. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE WHISTLER 1675
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual WHISTLER 1675 will begin.