User manual X10 DC8700P

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual X10 DC8700P. We hope that this X10 DC8700P user guide will be useful to you.

Lastmanuals help download the user guide X10 DC8700P.


Mode d'emploi X10 DC8700P
Download
Manual abstract: user guide X10 DC8700P

Detailed instructions for use are in the User's Guide.

[. . . ] Monitor PlusTM Supervised Security System With Digital Central Station Communicator PANIC ARM HOME ARM AWAY PANIC DISARM 15 · DISARM · 1· 3 5 · 13 11 · ·9· UNIT 7 PANIC SECURITY LIGHT · A· O· C · 1s tD ra ft ON OFF M · E · ZONES AWAY - ARM - HOME K 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 I· G · HOUSE BYPASS ZONES 9-16 Lamp Module ON - LIGHTS - OFF A· O· C BRIGHT DIM · · M E · ARM MONITOR AC POWER BATTERY LOW · K · I· G ENTRY INSTANT DELAY BATTERY ARM PANIC DISARM LIGHTS ON LIGHTS OFF ® TM MOTION DETECTOR DOOR/WINDOW SENSOR Monitored Security System, Model DC8700P READ THIS FIRST This equipment generates and uses radio frequency energy, and if not installed and used properly, that is, in strict accordance with the manufacturers instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for remote control security devices in accordance with the specifications in Sub-Parts B and C of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by unplugging the equipment, try to correct the interference by one or more of the following measures. [. . . ] Service Station Number: Number for the service station. Account number: Your 8 digit account number. Exit delay: The amount of time the console gives you to leave the house when armed. Entry delay: The amount of time you have to disarm the alarm when you enter your home. Delay before dialing: The amount of time the console waits after it has been triggered before calling the monitoring station (to give you time to disarm the system before it dials in case of a false alarm). Test Dial Frequency: How many days the console waits to call the service station to check-in. House/Unit Code to flash lights: (active only if the console is armed in the away mode). House/Unit Codes for Lived-in look: To control lights and appliances to make your home look lived in (active only if the console is armed in the away mode). The default settings are A-14, A-15, and A-16. 11. Daylight parameters: Sets dusk times for midwinter and midsummer to activate lived-in look lighting control (see option 10). Dusk times for the rest of the year are calculated automatically. Defaults are 4 PM in midwinter and 10 PM in midsummer. Preset off time: Time for the lights to turn off after they have been turned on automatically at dusk (when armed in the away mode). Daylight Savings Date: Date for daylight savings time. Panic Dialing ON/OFF: If this option is set to ON, the console dials out whenever PANIC is pressed. If this option is set to OFF, the console only dials out when PANIC is pressed and the system is armed. Chirp ON/OFF: If chirp is ON, the console chirps when it needs programming. Siren ON/OFF: If the siren is set to off, it will not be activated when the alarm is triggered, although the console still dials out. Flashing lights ON/OFF: If this option is turned off, the lights will not flash when the alarm is triggered, although the console still dials out. Tone or Pulse: To change the dialer to Touch Tone or Pulse dialing. The default is Tone dialing. Console Zone Indicators The console displays the status of the first eight zones. These indicators can display four states, as follows: Steady on: means that particular door or window is open. [. . . ] To turn the zone indicator off, and stop the armed indicator from flashing, press the LIGHT ON or LIGHT OFF button on the remote control. If a zone indicator is not on, the violated zone will have been one of the second eight zones. Press BYPASS to see which zone was tripped. · Be sure you set the Housecode on the POWERHORN to the same letter and number as downloaded to the Console. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE X10 DC8700P

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual X10 DC8700P will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag