[. . . ] ORCATM
Panic System
Owner's Manual
ORCA Panic System Model ORCA 2000
READ THIS FIRST
This equipment generates and uses radio frequency energy, and if not installed and used properly, that is, in strict accordance with the manu facturers instr uctions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for remote control security devices in accordance with the specifications in Sub-Parts B and C of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by unplugging the equipment, try to correct the interference by one or more of the following measures. [. . . ] This one can be placed in a special compartment on the dorsal fin of a 26" long Lucky ORCA Whale. * You can install a combination of 16 Panic Buttons and/or Keychain Remotes.
7
Setting up Lamp Modules
When the alarm trips, lamps connected to Lamp Modules set to A-1 (or other codes on request from the monitoring station - see pages 10 and 11) flash on and off for the duration of the alarm. After 4 minutes (or when you stop the alarm) the lamps stop flashing and remain on. You can also control Lamp Modules set to A-1 from the LIGHTS ON and LIGHTS OFF buttons on the Keychain Remote, or from the small buttons under the lid on the KR15A Panic Button. Choose a lamp you want to be a part of your Panic System. Make sure the lamp's on/off switch is on and plug the lamp into the Lamp Module. Plug the Lamp Module into any convenient outlet. Set the House Code and Unit Code dials on the Lamp Module to A-1 (or other codes on request from the monitoring station - see pages 10 and 11).
Setting up the POWERHORN
The POWERHORN Remote Powerline Siren responds to signals transmitted by the Console (over your house wiring). When you trip the panic alarm, the POWERHORN is also tripped and continues to sound until about 4 seconds after the alarm is stopped. Set House Code and Unit Code dials on the POWERHORN to A-1 2. Plug the POWERHORN into a standard AC outlet (not one controlled by a wall switch).
WARNING: THE POWERHORN is very loud!Do not stand near it when you trip the alarm. Prolonged exposure could cause permanent hearing damage.
15 13 11
1
3 5 7
15 ·
·
1· 3 5
·
13 11
· ·9·
UNIT
9
UNIT
7
O M K
A
C E G
M
·
A· O· C
· ·
E
·
K
I
HOUSE
I·
G
·
HOUSE
Lamp Module
Power Horn
8
SETTING UP FOR MONITORING BY ORCA
Introduction to digital monitoring
The ORCA Panic System incorporates the same digital communicator technology found in expensive high-end security systems. Features supported include remote configuration and alarm type confirmation. When the Console is tripped, a loud piercing siren sounds and lights connected to Lamp Modules flash on and off. It then calls ORCA Monitoring Services and sends a digitally coded message allowing the station operator to identify your address, telephone number and even the type of alarm which occurred (in this case Panic). Note: Although you can register your system as soon as it has been installed, the ORCA Monitoring Services will not respond to alarm calls until the signed monitoring agreement has been received and you have been allocated your security code which will be notified to you by return.
Calling Customer Service
After you have registered your system you can easily call the customer service center if you need help, or to change any of the default options as follows: · Set the Console slide switch to RUN1 or RUN2. The Console automatically dials the customer service number. · Pick up the handset of a phone connected to the same line as the Console. Alternatively, you can dial the telephone number in the usual way with any telephone connected to the same line as the Console - just pick up the telephone and dial 1-800-FOR ORCA (1-800-367-6722).
Registering with ORCA Monitoring Services.
Once you have installed the system you are ready to set up for monitoring. To do this, all you need to do is: · Fill out the enclosed monitoring agreement and mail or fax it to ORCA Monitoring Ser vices. · Call ORCA Monitoring Services at 1-800 FOR ORCA (1-800-367-6722) and follow the instructions to have your system initialized.
9
Options downloaded by ORCA Monitoring Services
The options that are downloaded to your Console when you register it are listed below. [. . . ] · Plug the module into another outlet near the Console. · Check that the battery indicator on the Remote Control comes on when you press a button. Replace battery and re-install remote if necessary. · Check the House and Unit codes for the Panic Button (default A-1). [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE X10 ORCA2000
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.