[. . . ] The antenna(s) used with this device must satisfy the antenna co-location requirements of 47 C. F. R. 1. 1307(b)(3).
NOTICE!
Do not modify this repeater for any reason. Refer service of this repeater to qualified technicians only. When the repeater become abnormal, such as the overheating, smoke smell of burning, etc. , turn the main power switch off and disconnect the Main Power Source connector from the rear of the VXR-9000 immediately. [. . . ] This function is ignored on the channel which is programmed to the transmitter power to the "Mid" or "Low" level by your VERTEX STANDARD dealer.
TEST TONE
Press (or Press and hold in for one second) the PF key assigned to "Test Tone" to generate the Test Tone Signal, as programmed by your VERTEX STANDARD dealer. Press (or Press and hold in for one second) this key again to stop the generation of the Test Tone. Press (or Press and hold in for one second) this key while press and holding the PTT switch to transmit the Test Tone Signal, as programmed by your VERTEX STANDARD dealer.
TX POWER LOW
Press (or Press and hold in one second) the PF key assigned to "TX Power Low"to set the transmitter power to the "Low" level. Press (or press and hold in one second) this key again to return to "Original" power level (determined via programming by your VERTEX STANDARD dealer). The output impedance requirement is 50 Ohms.
6
VXR-9000 FM REPEATER OPERATING MANUAL
DB-25 CONNECTOR PORT
The VXR-9000 repeater is provided with a 25-pin DB25F female connector for interconnections to accessories. Use a DB-25M 25-pin male connector to connect accessories to the repeater. The pins on the accessory connector are explained in detail as follows:
Pin 5: TX ATT
This output is intended for controlling an external coaxial switching relay. It is an open drain output which can sink approx. The delay time which is between the repeater cause to transmit mode and this port switches to ground can be programmed by your VERTEX STANDARD dealer.
Pin 1: GND
Chassis ground for all logic levels and power supply return.
Pin 6: DISC OUT
[ANALOG OUTPUT] (WIDE-BAND: 0 ~ 3, 000 HZ) Received signals with full system deviation produce 350 mVrms audio at this pin. The output impedance is 600 Ohm, and is extracted before the de-emphasis and squelch circuitry. Use shielded cable to connect to this pin, and connect the shield to GND.
Pin 2: +13. 6 V
[POWER SUPPLY] This pin provides 13. 6 Volts, 2. 0 A, DC from the repeater supply. There is a internal 3 A fuse to prevent damage to the repeater.
Pin 3: TX AF IN
[ANALOG TRANSMITTER INPUT] (VOICE BAND: 300 ~ 3, 000 HZ) This pin is audio input. This audio is injected before the splatter filter stage, so excess signal input levels are clipped. Use shielded cable to connect to this pin, and connect the shield to GND.
Pin 7: N. C.
No connection.
Pin 8: RSSI
[ANALOG OUTPUT] A DC voltage proportional to the strength of the signal currently being received (Receiver Signal Strength Indicator) is provided on this pin. This low impedance output is generated by the receiver IF sub-system and buffered by an internal op-amp. Typical voltages are graphed as follows:
(DC V)
Pin 4: TONE IN
[TRANSMITTER INPUT] (SUB-AUDIBLE BAND: 5 ~ 250 HZ) This pin is sub-audiable tone input. The input impedance is 600 Ohms, and has a flat response characteristic (repeater deviation is constant for a given signal level over the frequency range of 5 ~ 250 Hz). Injecting too high a voltage here causes over-deviation of CTCSS or DCS, degrading performance. Use shielded cable to connect to this pin, connecting the shield to GND.
RSSI Output Voltage
2. 5 2. 0 1. 5 1. 0 0. 5 0 60 70 80 90 100 110 120 (dBm)
Input Signal Level
Pin 9: COAX. SW
[LOGIC OUTPUT (ACTIVE LOW)] This output is intended for controlling an external coaxial switching relay. It is an open drain output which can sink approx. This signal only switches if the repeater has been programmed for "SIMPLEX" mode. If programmed for "DUPLEX, " the signal remains open (high impedance) at all time.
DB-25 PIN NUMBERING
VXR-9000 FM REPEATER OPERATING MANUAL
7
DB-25 CONNECTOR PORT
Pin 10, 13, 15, 16, 17, 18, 19, 21: Pin PROGRAMMABLE I/O "0" ~ "7"
The VXR-9000 provides eight ports (PIO) that can be programmed for various input or output signals, or for control functions. [. . . ] While operating from a backup battery, the repeater requires approximately 7 amperes at 12 Volts during transmit. Never short the "Backup Power Sorce" Terminals, when the Battery Charge switch (located on the PA Unit) is set to "ON. "
To RX Antenna
BACKUP
B ACK UP
MAIN
RX TX
INPUT DC 13. 6V EXT GND ACC
To TX Antenna
BLACK
RED
Supplied DC Power Code
Backup Battery (12 V, 55 Ah)
TYPICALLY SETUP
10
VXR-9000 FM REPEATER OPERATING MANUAL
BLACK
RED
ACCESSORIS & OPTION
Supplied Accessories
DC Power Cord (T9023499) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-A Blade Fuse (Q0000075) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Knob Cap (RA0506900) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE YAESU VXR-9000
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual YAESU VXR-9000 will begin.