Manual abstract: user guide YAMAHA CLP-260

Detailed instructions for use are in the User's Guide.

[. . . ] To change the setting use a "minus" screwdriver to rotate the selector dial so that the correct voltage appears next to the pointer on the panel. SPECIAL MESSAGE SECTION PRODUCT SAFETY MARKINGS: Yamaha electronic products may have either labels similar to the graphics shown below or molded/stamped facsimiles of these graphics on the enclosure. The explanation of these graphics appears on this page. Please observe all cautions indicated on this page and those indicated in the safety instruction section. ENVIRONMENTAL ISSUES: Yamaha strives to produce products that are both user safe and environmentally friendly. [. . . ] For example, a single MIDI sequence recorder could be used to "play" two different instruments or tone generators. One of the instruments or tone generators could be set to receive only on channel 1, while the other is set to receive on channel 2. In this situation the first instrument or tone generator will respond only to channel-1 information transmitted by the sequence recorder, while the second instrument or tone generator will respond only to channel-2 information. This allows the sequence recorder to "play" two completely different parts on the receiving instruments or tone generators. In any MIDI control setup, the MIDI channels of the transmitting and receiving equipment must be matched for proper data transfer. An "ALL" receive mode is also available, which allows reception on all 16 MIDI channels. MIDI OUT MIDI IN MIDI THRU MIDI IN DOU-10 Tone Generator (Set to receive on MIDI channel 2) Clavinova (Set to receive on MIDI channel 1) CLP-810S 12 MIDI Functions q Setting the Clavinova MIDI Channels ZSimultaneously press and hold the A-1 and C#0 keys. XPress the key on the keyboard corresponding to the desired MIDI transmit or receive channel. * CRelease the A-1 and C#0 keys. * Keys C1 through D#2 on the keyboard are used to set the MIDI transmit channel. The E2 key turns transmission "OFF" if you don't want the Clavinova to transmit MIDI data. Keys C4 through D#5 are used to set the MIDI receive channel as shown in the illustration below. The E5 key sets the receive mode to "ALL". NOTE · When the power is initially turned ON, MIDI receive is set to the ALL mode and the transmit channel is set to 1. A-1 C#0 C1 24 7 9 11 E2 D#2 14 16 C4 24 7 9 11 E5 D#5 14 16 1 3 5 6 8 10 12 13 15 1 3 5 6 8 10 12 13 15 For setting the transmit channel. (C1 ~ D#2) OFF For setting the receive channel. PROGRAM CHANGE Data format: [CnH] -> [ppH] CnH = Program event (n = channel number) ppH = Program change number Program change number Vioce Bank MSB Bank LSB Program Change Number PIANO 0 112 0 PIANO (Variation) 0 113 0 (6) Effect1 Depth ( Reverb Send Level ) ccH Parameter Data Range (vvH) 5BH Effect1 Depth 00H. . . 7FH Adjusts the reverb send level. 3 MODE MESSAGES Data format: [BnH] -> [cc] -> [vv] BnH = Control event (n = channel number) cc = Control number vv = Data Range 5. SYSTEM REALTIME MESSAGES Active sensing [FEH] · Transmitted every 200 milliseconds. · If a signal is not received via MIDI for more than 400 milliseconds, the same processing will take place for All Sound Off, All Notes Off and Reset All Controllers as when those signals are received. · Caution: If an error occurs during MIDI reception, the Damper and Soft effects for all channels are turned off and an All Note Off occurs. (1) All Sound Off ccH Parameter Data Range (vvH) 78H All Sound Off 00H Switches off all sound from the channel. Does not reset Note On and Hold On conditions established by Channel Messages. (2) Reset All Controllers ccH Parameter Data Range (vvH) 79H Reset All Controllers 00H Resets controllers as follows. Controller Value Expression 127 (max) Damper Pedal 0 (off) Sostenuto 0 (off) Soft Pedal 0 (off) 6. SYSTEM EXCLUSIVE MESSAGES (Universal System Exclusive) (1) Universal Realtime Message Data format: [F0H] -> [7FH] -> [XnH] -> [04H] -> [01H] -> [ll H] -> [mmH] -> [F7H] CLP-810S 15 MIDI Data Format MIDI Master Volume · Simultaneously changes the volume of all channels. · When a MIDI master volume message is received, the volume only has affect on the MIDI receive channel, not the panel master volume. F0H 7FH 7FH 04H 01H ll H mmH F7H or F0H 7FH XnH 04H 01H ll H mmH F7H = Exclusive status = Universal Realtime = ID of target device = Sub-ID #1=Device Control Message = Sub-ID #2=Master Volume = Volume LSB = Volume MSB = End of Exclusive = Exclusive status = Universal Realtime = When n is received n=0~F, whichever is received. X = don't care = Sub-ID #1=Device Control Message = Sub-ID #2=Master Volume = Volume LSB = Volume MSB = End of Exclusive (2) XG Native Bulk Data (reception only) Data format: [F0H] -> [43H] -> [0nH] -> [4CH] -> [aaH] -> [bbH] -> [hhH] -> [mmH] -> [ll H] -> [ddH] ->. . . -> [ccH] -> [F7H] F0H Exclusive status 43H YAMAHA ID 0nH When received, n=0~F. 4CH Model ID of XG aaH ByteCount bbH ByteCount hhH Address High mmH Address Mid ll H Address Low ddH Data | | | | ccH Check sum F7H End of Exclusive · Receipt of the XG SYSTEM ON message causes reinitialization of relevant parameters and Control Change values. Allow sufficient time for processing to execute (about 50 msec) before sending the Clavinova another message. · XG Native Parameter Change message may contain two or four bytes of parameter data (depending on the parameter size). [. . . ] 4, Jakarta 12930, Indonesia Tel: 21-520-2577 PORTUGAL Valentim de Carvalho CI SA Estrada de Porto Salvo, Paço de Arcos 2780 Oeiras, Portugal Tel: 01-443-3398/4030/1823 CENTRAL & SOUTH AMERICA MEXICO Yamaha de Mexico S. A. De C. V. , Departamento de ventas Javier Rojo Gomez No. 1149, Col. Tel: 686-00-33 KOREA Cosmos Corporation #131-31, Neung-Dong, Sungdong-Ku, Seoul Korea Tel: 02-466-0021~5 GREECE Philippe Nakas S. A. Navarinou Street 13, P. Code 10680, Athens, Greece Tel: 01-364-7111 SWEDEN Yamaha Scandinavia AB J. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE YAMAHA CLP-260

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual YAMAHA CLP-260 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag