Detailed instructions for use are in the User's Guide.
[. . . ] , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
IMPORTANT
Check your power supply Make sure that your local AC mains voltage matches the voltage specified on the name plate on the bottom panel. In some areas a voltage selector may be provided on the bottom panel of the main keyboard unit near the power cord. Make sure that the voltage selector is set for the voltage in your area. The voltage selector is set at 240V when the unit is initially shipped. [. . . ] 2 Set the storage device into the appropriate receiving mode. (Refer to the device's operating manual for instructions. )
CLP-811/611
Configuration Functions (FUNCTION mode)
35
3 At the Clavinova, select function F13 and move to subfunction 13-8 BulkDump. The screen displays Working while transmission is in progress, and then Completed to indicate that the operation is finished. It then returns to the original Bulk Dump screen. 5 When transfer is finished, you can terminate FUNCTION mode and resume normal play. Run a MIDI cable from MIDI OUT on the storage device to MIDI IN at the Clavinova. Start transmission from the storage device. (Refer to the device's operation manual. ) The Clavinova automatically receives and restores the incoming data. The restored data is then available for normal playback.
NOTE
F14/F15. Backup (Backup ON/OFF settings)
(F14 on the CLP-611; F15 on the CLP-811. ) The Clavinova's backup feature allows you to retain selected settings while power is off so that they can be restored when power comes back ON. Each BACKUP subfunction sets backup ON or OFF for a specific group of settings. · If backup for a group is set OFF, all settings within that group return to their factory defaults each time power comes on. (A listing of factory defaults appears on page 47. ) If backup is set ON, then existing settings are automatically restored. · Memory backup remains effective for about a week, after which all settings will return to their factory defaults. If you wish to retain your settings for a long period of time, please be sure to switch the Clavinova on for at least a few minutes each week. 1 To access this setting, enter FUNCTION mode and go to the main function F14 (CLP-611) or F15 (CLP-811).
· It is not possible to reload data into a different Clavinova model. Data from a CLP-811, for example, can be loaded into another CLP-811, but not into a CLP-611. · You cannot send or receive bulk data while the Clavinova is in RECORDING mode or while it is playing back recorded data.
1
2
NORMAL
ROOM
MEDIUM
TEMPO
· You cannot receive bulk data while the Clavinova is in FUNCTION mode. · When transmitting bulk data, the Clavinava will not transmit other types of MIDI data and will not recognize incoming MIDI messages.
BRILLIANCE
REVERB
EFFECT
TOUCH
2 Next, press [+/YES] to enter the subfunction group. Then use [t], [s] to move among the different subfunctions, and [-/NO], [+/YES] to set the values.
(On CLP-811 only:)
F14. MicRevDpt (Microphone reverb depth)
This function sets the reverb depth (intensity of reverb effect) applied to microphone input. (Note that this function is not available on the CLP-611. )
1 To access this setting, enter FUNCTION mode and go to main function F14.
Subfunctions 14. 1/15. 1 Voice (Voice settings) 14. 2/15. 2 MIDI (MIDI settings) 14. 3/15. 3 Tune (Tuning and temperament settings) 14. 4/15. 4 Pedal (Pedal settings) 14. 5/15. 5 Display (Display mode)
Values: ON, OFF Default: OFF* * But note that the Backup ON/OFF settings themselves, as well as recorded performance data, are always backed up.
1
2
NORMAL
ROOM
MEDIUM
TEMPO
BRILLIANCE
REVERB
EFFECT
TOUCH
2 Press [-/NO] or [+/YES] to change the setting. Values: 0, . . . , 20 Default: 10
36
CLP-811/611
Configuration Functions (FUNCTION mode)
Parameters in Each Group 14. 1/15. 1 Voice (Voice settings)
· · · · · · · · · · · · · Voice selection DUAL mode ON/OFF status and voice combination The [F4. DualFunc. ] settings (for each voice combination) SPLIT mode ON/OFF status and voice combination The [F5. SplitFunc. ] settings (for each voice combination) REVERB type and depth EFFECT type and depth (for each voice) BRILLIANCE setting VARIATION ON/OFF status (for each voice) TOUCH setting All [F6. OrganEdit] settings All [F7. Metronome] settings The [F14. MicRevDpt] setting (CLP-811 only)
14. 2/15. 2 MIDI (MIDI settings)
All MIDI settings ([F13. MIDIFunc. ] settings 13-1 to 13-6)
14. 3/15. 3 Tune (Tuning and temperament settings)
· · · · Current TRANSPOSE setting Keyboard fine tuning ([F1. Tune] setting) Key-by-key fine tuning ([F2. KTune] settings) Temperament selection ([F3. Scale] settings)
14. 4/15. 4 Pedal (Pedal settings)
· Left-pedal function ([F9. L. Pedal] setting) · Damper-pedal depth ([F10. DamperDpt] setting) · Number of damper-pedal levels ([F11. Damper] setting)
14. 5/15. 5 Display (Display mode)
Display mode ([F8. Display] setting)
·
To reset all values to their factory defaults. . .
Switch the power OFF, then hold down the highest key on the keyboard (key C7) and switch the power back on. Note that this operation will also delete all recorded performance data. [. . . ] Cords should also be disconnected when there is a high probability of lightening and/or electrical storm activity.
10.
This product may be equipped with a polarized plug (one blade wider than the other). If you are unable to insert the plug into the outlet, turn the plug over and try again. If the problem persists, contact an electrician to have the obsolete outlet replaced. Do NOT defeat the safety purpose of the plug.
3.
Care should be taken that objects do not fall and liquids are not spilled into the enclosure through any openings that may exist.
11.
Some electronic products utilize external power supplies or adapters. [. . . ]