Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual YAMAHA MR842 MR1242 MR1642. We hope that this YAMAHA MR842 MR1242 MR1642 user guide will be useful to you.
Lastmanuals help download the user guide YAMAHA MR842 MR1242 MR1642.
Manual abstract: user guide YAMAHA MR842 MR1242 MR1642
Detailed instructions for use are in the User's Guide.
[. . . ] Any notes being held by the damper or sostenuto pedal will continue to sound until the pedal is released. (5) Omni Off (reception only) ccH Parameter Data Range (vvH) 7CH Omni Off 00H Same processing as for All Notes Off. (6) Omni On (reception only) ccH Parameter Data Range (vvH) 7DH Omni On 00H Same processing as for All Notes Off. [. . . ] (8) Poly (reception only) ccH Parameter Data Range (vvH) 7FH Poly 00H Same processing as for All Sound Off. · When Control Change is turned OFF, Control Change messages will not be transmitted or received. · Local on/off, OMNI on/off are not transmitted. (The appropriate note off number is supplied with "All Note Off" transmission). · When a voice bank MSB/LSB is received, the number is stored in the internal buffer regardless of the received order, then the stored value is used to select the appropriate voice when a program change message is received. This mode will not change when the instrument receives MONO/POLY mode message.
(9) Harmonic Content (reception only) ccH Parameter Data Range (vvH) 47H Harmonic Content 00H. . . 7FH (10) Release Time (reception only) ccH arameter ata Range (vvH) 48H elease Time 00H. . . 7FH (11) Attack Time (reception only) ccH Parameter Data Range (vvH) 49H Attack Time 00H. . . 7FH (12) Brightness (reception only) ccH Parameter Data Range (vvH) 4AH Brightness 00H. . . 7FH (13) Portamento Control ccH Parameter 54H Portamento Data Range (vvH) 00H. . . 7FH
(14) Effect1 Depth (Reverb Send Level) ccH Parameter Data Range (vvH) 5BH Effect1 Depth 00H. . . 7FH Adjusts the reverb send level. (15) Effect3 Depth (Chorus Send Level) ccH Parameter Data Range (vvH) 5DH Chorus Depth 00H. . . 7FH
2
YDP-161/141 Data List / Daten-Liste / Liste des données / Lista de datos
4. PROGRAM CHANGE
Data format: [CnH] [ppH]
CnH = Program event (n = channel number) ppH = Program change number P. C. #=Program Change number
YDP-161 Grand Piano 1 Grand Piano 2 E. Piano 1 E. Piano 2 Harpsichord 1 Harpsichord 2 Vibraphone Church Organ 1 Church Organ 2 Strings YDP-141 Grand Piano 1 Grand Piano 2 E. Piano 1 Harpsichord Church Organ Strings MSB 0 0 0 0 0 0 0 0 0 0 MSB 0 0 0 0 0 0 LSB 122 112 122 122 122 123 122 123 122 122 LSB 122 112 122 122 123 122 P. C. # 1 1 6 5 7 7 12 20 20 49 P. C. # 1 1 6 7 20 49
7. SYSTEM EXCLUSIVE MESSAGES (Universal System Exclusive)
(1) Universal Realtime Message
Data format: [F0H] [7FH] [XnH] [04H] [01H] [llH] [mmH] [F7H] MIDI Master Volume
· Simultaneously changes the volume of all channels. 4CH = Model ID of XG hhH = Address High mmH = Address Mid llH = Address Low ddH = Data | F7H = End of Exclusive Data size must match parameter size (2 or 4 bytes). When the XG System On message is received, the MIDI system will be reset to its default settings. The message requires approximately 50ms to execute, so sufficient time should be allowed before the next message is sent. (2) XG Native Bulk Data (reception only)
Data format: [F0H] [43H] [0nH] [4CH] [aaH] [bbH] [hhH] [mmH] [llH] [ddH] . . . [ccH] [F7H]
F0H = Exclusive status 43H = YAMAHA ID 0nH = When received, n=0~F. 4CH = Model ID of XG aaH = ByteCount bbH = ByteCount hhH = Address High mmH = Address Mid llH = Address Low ddH = Data | | | | ccH = Check sum F7H = End of Exclusive · Receipt of the XG SYSTEM ON message causes reinitialization of relevant parameters and Control Change values. Allow sufficient time for processing to execute (about 50 msec) before sending this instrument another message. · XG Native Parameter Change message may contain two or four bytes of parameter data (depending on the parameter size). · For information about the Address and Byte Count values, refer to Table 1 below. [. . . ] · For information about the Address and Byte Count values, refer to Table 1 below. Note that the table's Total Size value gives the size of a bulk block. Only the top address of the block (00H, 00H, 00H) is valid as a bulk data address.
9. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE YAMAHA MR842 MR1242 MR1642
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual YAMAHA MR842 MR1242 MR1642 will begin.