User manual YAMAHA NUAGE V1.1 SUPPLEMENTARY MANUAL
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual YAMAHA NUAGE. We hope that this YAMAHA NUAGE user guide will be useful to you.
Lastmanuals help download the user guide YAMAHA NUAGE.
Manual abstract: user guide YAMAHA NUAGEV1.1 SUPPLEMENTARY MANUAL
Detailed instructions for use are in the User's Guide.
[. . . ] • Upgrades to the NUAGE Workgroup Manager application and system software and any changes made to functionality and/or specifications will be announced on the following website. http://www. yamahaproaudio. com/ • Windows is a registered trademark of Microsoft® Corporation in the United States and other countries. • Apple, Mac, and Macintosh are trademarks of Apple Inc. , registered in the U. S. • Company and product names used in this manual are trademarks or registered trademarks of their respective companies. [. . . ] Click to add the device or DAW application
to the Workgroup area in the upper half of the window.
1. Connect the devices and the computers
running the DAW applications using Ethernet cables.
2. Turn on the devices and launch the DAW
applications.
NOTE
When you turn on a device or launch a DAW application for the first time, you will be asked to confirm whether you want to add it to the Workgroup. In the event that this confirmation message is not displayed, carry out the procedure from Step 3 below to add the device or DAW applications manually.
3. Double-click the NUAGE Workgroup
Manager icon in the system tray (Windows) or menu bar (Mac) to open NUAGE Workgroup Manager.
Identifying a device or DAW application
To identify any device or DAW application displayed in NUAGE Workgroup Manager, click the corresponding Identify button on the Main window (page 8). When you do so, the lamp on the device or DAW application will respond by flashing for a few seconds.
4. Select a device or DAW application in the
Device/DAW List area in the lower half of the window.
NUAGE Workgroup Manager Operation Manual
4
Using the Application
Configuring devices and DAW applications
To configure any device or DAW application displayed in NUAGE Workgroup Manager, click the corresponding Property button. When you do so, a setting window for the device or DAW application will be displayed. The settings that can be made on this window will depend on the device or DAW application.
Making connections
Connect the various system components according to the following example.
DAW A (Computer A)
DAW B (Computer B)
KVM switch
KVM switch
LCD
LCD
Nuage Fader
Nuage Master
Switching between multiple DAW applications
The buttons from the DAW Select section of a Nuage Fader or Nuage Master can be used to switch between multiple DAW applications. In addition, KVM switches can be used to ensure that LCD windows also change at the same time. By way of example, the following describes the connections and settings that need to be made in order to switch between two DAW applications when using one Nuage Fader and one Nuage Master.
Mouse and keyboard Video RS-232C Video (from splitter)
Mouse/ Keyboard
Video, mouse and keyboard
NOTE
• Ethernet connections are not shown in the above diagram. To open this window, click Property (page 8) on the Main window.
Component names and functions
Click to open the Property window (page 8).
!
1 2 4 5 3
Click to add the device or DAW application selected in the Device/DAW list to the Workgroup and move it to the Workgroup area.
@
Click to remove the device or DAW application selected in the Workgroup area from the Workgroup.
# Unavailable Workgroup Member 1 Name
This area displays devices and DAW applications not added to the current Workgroup. If your computer is fitted with more than one network adaptor, devices and DAW applications from any network connected via an adaptor not selected under Network Interface on the Setup window will be grayed out. The lock icon will change depending on whether or not the device or DAW application in question has been added to another Workgroup. Added to another Workgroup: Not added to another Workgroup:
This field displays the name of the device or DAW application. To change a name, you can simply click Property for the device or DAW application in the Workgroup area of the Main window.
2 Version
This item displays the current version (shown as “x. x. x” here). Specifically, it displays the firmware version for devices, the NUAGE Extension version for Nuendo, and the NUAGE PT Bridge version for Pro Tools.
3 Check for Update
Click to confirm via the Internet whether a device's firmware is up-to-date. If a newer version is available, please install it according to the on-screen instructions.
4 MAC Address
This item displays the MAC address.
5 Status
If a problem has occurred on the device, an error message will be displayed here.
NUAGE Workgroup Manager Operation Manual
8
Descriptions of Windows
Setup window
1 Network Interface
This drop-down list is used to select the network adaptor on your computer that will be used with NUAGE Workgroup Manager.
2 Auto Register
Select this check box to turn the Automatic Registration function on and clear to turn it off. If devices or DAW applications not currently in the Workgroup are identified on the network while this function is on, you will be asked whether or not you wish to add them to the Workgroup.
3 KVM Serial Data
These fields are used to enter the ASCII messages to be sent to KVM switches in order to switch them. For details on this data, refer to the manual that came with the KVM switch in question. Control characters should be entered as follows. [. . . ] To open this window, click Setup (page 7) on the Main window.
4 RS232C Parameters
This area is used to set parameters for the data transmitted from the RS-232C port the rear of the Nuage Fader or Nuage Master. Parameter
Bit Rate [bps]
Settings
4800, 9600, 19200, 38400, 57600, and 115200 7 and 8 1 and 2 NONE, EVEN, and ODD
Component names and functions
Data Bits Stop Bits Parity Bits
1 2
About window
3
Overview
4
The About window displays the current NUAGE Workgroup Manager version (shown as “x. x. x” here). To open this window, click About (page 7) on the Main window.
NUAGE Workgroup Manager Operation Manual
9
Troubleshooting
Troubleshooting
A device or DAW application is not displayed in the Device/DAW List area.
• Devices: Ensure that the device is turned on. • DAW applications: Ensure that the application is running. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE YAMAHA NUAGE
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual YAMAHA NUAGE will begin.