[. . . ] This allows you to exclude just the DCA group name from DCA group Recall Safe and Selective Recall. If the WITH NAME button is on, Recall Safe and Selective Recall will apply to the DCA group names of DCA groups for which these functions are on. If the WITH NAME button is off, DCA group names are excluded from Recall Safe and Selective Recall.
Select the monitor source from the panel (from V1. 05)
When selecting a monitor source from the panel in V1. 04 or earlier, you could simultaneously select one source from [2TR A1][2TR D3] or [DEFINE] and one source from [STEREO A]/[STEREO B] (including LCR), for a maximum total of two sources. [. . . ] In V1. 05 and later, turning on one key will turn off the other keys, allowing you to select a single monitor source more rapidly. If you want to select two sources simultaneously (as in V1. 04 and earlier), press the corresponding panel keys simultaneously, or use the MONITOR screen.
EN
Parameter operation for Recall Safe/ Selective Recall (from V1. 12)
When using Recall Safe or Selective Recall, there has been a change in the behavior of parameters of which only one exists for each pair of adjacent odd-numbered/even-numbered channels or modules (see owner's manual p. 165). If Recall Safe or Selective Recall is specified for only one of these channels or modules, the parameters will behave as follows. · PAIR Forcibly turned off (pairing will be defeated). · GATE STEREO LINK · COMP STEREO LINK · GEQ LINK LINK parameters will be forcibly turned off (link will be defeated). · DELAY GANG · ATT GANG GANG parameters will be recalled. If GANG turns On because of the recall, the relative differences of the DELAY and ATT parameter values following the recall will be maintained when they are edited. · MS DECODE · FIXED/VARI These will not be recalled. · PAN MODE The PAN MODE parameter will be recalled. If you want the timing of the change to be synchronized, use the FADE TIME screen to specify a START OFFSET. · Do not perform scene store/recall operations in the Y96K's update waiting screen. If you do so, the screen will become inoperable for up to 30 seconds.
Note
Before turning on the MONITOR button, you must select the same port as the monitor output on the DME series unit and as the monitor input for the PM5D. To specify the DME series unit monitor output, use the "Monitor Out" dialog box of DME Designer, accessed by [Tools] menu [Monitor]. To specify the PM5D monitor input, use the MONITOR PORT field on the SETUP page of the DME CONTROL screen.
DME64N/24N version (from V1. 12)
In order to use the DME CONTROL functionality, the PM5D must be V1. 12 or higher, and all connected DME64N/24N units must be version 1. 1 or higher.
Newly added bulk dump data types (from V1. 05)
The following data types can now be handled by bulk dump.
Data name (D0) Data Number (D1, 2) tx/rx Function
`K' `V' `L' `U'
512 Surround Setting tx/rx (Current Data) & Request 512User Defined Keys tx/rx (Current Data) & Request 512MIDI Remote & tx/rx (Current Data) Request 512Fader Mode & tx/rx (Current Data) Request
SETUP data compatibility (from V1. 05)
SETUP data created on system software V1. 05 or later cannot be loaded into a system that's running V1. 03 or earlier. However, SETUP data created on system software V1. 03 or earlier can be loaded by a system that's running V1. 05 or later.
Scene data compatibility (from V1. 10)
In conjunction with Y96K card support, compatibility of scene data (ALL DATA, SCENE MEMORY, SCENE MEMORY with LINKED LIBRARY) has been changed as follows. Scene data created with system software V1. 10 or later cannot be loaded into a system running V1. 04 or earlier. However, scene data created on a system running V1. 04 or earlier can be loaded into a system running V1. 10 or later. In this case, the Y96K settings will remain as they were prior to loading. [. . . ] However, scene data created on a system running V1. 04 or earlier can be loaded into a system running V1. 10 or later. In this case, the Y96K settings will remain as they were prior to loading. If you save this data on a system running V1. 10 or later, the data size will increase by the amount required for Y96K support.
A note regarding scenes/libraries immediately after system startup
After the system is started up, the PM5D takes several minutes to transfer scene/library data within internal memory. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE YAMAHA PM-210
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.