Detailed instructions for use are in the User's Guide.
[. . . ] 2. 1. 7 After touch After touch is received in accordance with the reception channel of each mode. 2. 1. 8 Channel mode message
cntrl# 120 121 123 Parameter All Sound Off Reset All Controller All Notes Off data rng 0 0 0
3. System exclusive message
3. 1 Parameter change The TG55 transmits and receives the following eight parameter change types. [. . . ] Multi Data Performance Data Normal Voice Data Drum Voice Data Setup Data Program Change Table Switch Remote Master Tuning
Perfor -mance
3) direct : In voice mode, voice 00 63 correspond to the program change data 00 63. INT1, 2, PRE 1-4, and CARD1-4 change in accordance with the program bank change. Program change data 64 127 are not received. In performance mode, performance 00 63 correspond to the program change data 00 63. INT1, PRE1, 2, and Card 1, 2 change in accordance with the program bank change. Program change data 64 127 are not received. In Multi mode, each INST program changes in accordance with the above. are assigned as follows in accordance with the mode.
Bn 00 xx 20 xx Internal1 Voice Internal2 Voice Preset1 Voice Preset2 Voice Preset3 Voice Preset4 Voice Card1 Voice Card2 Voice Card3 Voice Card4 Voice Internal1 Performance Preset1 Performance Preset2 Performance Card1 Performance Card2 Performance Internal1 Multi Internal1 Voice(multi) Internal2 Voice(multi) Preset1 Voice (multi) Preset2 Voice (multi) Preset3 Voice (multi) Preset4 Voice (multi) Card1 Voice(multi) Card2 Voice(multi) Card3 Voice(multi) Card4 Voice(multi) Internal1 Perf(multi) Preset1 Perf (multi) Preset2 Perf (multi) Card1 Perf(multi) Card2 Perf(multi) Data (dec. ) 00, 00 00, 03 00, 02 00, 05 00, 08 00, 11 00, 01 00, 04 00, 07 00, 10 00, 64 00, 66 00, 69 00, 65 00, 68 00, 16 00, 32 00, 35 00, 34 00, 37 00, 40 00, 43 00, 33 00, 36 00, 39 00, 42 00, 80 00, 82 00, 85 00, 81 00, 84
The parameter change reception cannot be turned off with the MIDI switches, except for Device Number off. 3. 1. 1 TG55 Data parameter change (1) Format
11110000 01000011 0001nnnn 00101001 0000gggg 0sssssss 0ppppppp 0ppppppp 0vvvvvvv 0vvvvvvv 11110111 F0 43 nnnn 29 gggg sssssss ppppppp ppppppp vvvvvvv vvvvvvv F7
= Device Number = = = = = = Parameter Group Number Parameter Sub Group Number Parameter Number MS7bit Parameter Number LS7bit Data Value MS7bit Data Value LS7bit
(2) Parameter Group Number, Sub Group Number
Parameter Group Name Multi Data Performance Data Normal Voice Data Drum Voice Data Setup Data Program Change Table Switch Remote *1:1. . 16;Inst Number, 0;common data *2:1. . 4;Layer Number, 0;common data *3:0=Voice *4:36. . 84=Key Number, 0;common data *5:0=syn *6:Program Number gggg 0 1 2 3 4 7 8 sssssss 0, 1. . 16 0, 1. . 4 0 0, 36. . 84 0 0. . 63 0 *1 *2 *3 *4 *5 *6
(3) Parameter Number, Data Value See the appended table 1.
4) table : Reception is carried out in accordance with the PROGRAM CHANGE TABLE.
2
(4) Operation (Transmission) When the data is edited with the panel switch, the parameter change is transmitted in accordance with the previously stated transmission conditions. Normal Voice bulk dump Drum Voice bulk dump Performance bulk dump Multi bulk dump Synthesizer Setup bulk dump Sample bulk dump (1) Format
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 29 30 31 32 11110000 01000011 0000nnnn 01111010 0bbbbbbb 0bbbbbbb 01001100 01001101 00100000 00100000 0ddddddd 0ddddddd 0ddddddd 0ddddddd 0ddddddd 0ddddddd 00000000 00000000 0ttttttt 00mmmmmm 0vvvvvvv 0sssssss 11110111 F0 43 nnnn 7A = Device Number
5 Sample Dump
For the sample dump the TG55 uses the Sample Dump Standard and the SY99 Sample Bulk Dump. For transmission, the above two data types are transmitted successively when "Sample Dump of Sample Utility" is executed. When receiving Sample Dump Standard Dump Request, and the SY99 Sample Bulk Dump Request, each data type is transmitted. With the Sample Dump Standard and the SY99 Sample Bulk Dump, $1f is the upper limit of the Sample (memory) Number; numbers exceeding this are handled as $1f. Sample Dump Standard
DUMP REQ ACK NAK CANCEL WAIT DATA PACKET DUMP HEADER pp cc ss ee ff gg hh ii jj kk ll F0, 7E, cc, 03, ss, ss, F7 F0, 7E, cc, 7F, pp, F7 F0, 7E, cc, 7E, pp, F7 F0, 7E, cc, 7D, pp, F7 F0, 7E, cc, 7C, pp, F7 F0, 7E, cc, 02, kk, <120 byte>, ll, F7 F0, 7E, cc, 01, ss, ss, ee, ff, ff, ff, gg, gg, gg, hh, hh, hh , ii, ii, ii, jj, F7 : : : : : : : : : : : packet number channel number sample number (LSB first) sample format (SY99 handles 8 16 bits. ) sample period (LSB first) sample length (LSB first) loop start (LSB first) loop end (LSB first) loop type (00=normal Loop, 01=alternate Loop, 7F=Loop off) running packet count(0-127)(Sequential packet No. ) checksum(XOR of 7E cc 02 kk <120 bytes>)
No. of bytes 4C(ascii"L") 4D(ascii"M") 20(ascii" ") 20(ascii" ") ddddddd = ddddddd = ddddddd = ddddddd = ddddddd = ddddddd = 00
C H E C K
Data Format Name(ascii) Data Format Name(ascii) Data Format Name(ascii) Data Format Name(ascii) Data Format Name(ascii) Data Format Name(ascii)
ss ff gg hh ii ff gg hh ii
S U 00 M ttttttt = Memory_type mmmmmmm = Memory Number vvvvvvv = data value sssssss = check_sum F7
6. Status FE (Active sensing)
a Reception If a signal is not output from MIDI for longer than approximately 300 msec after receiving FE, the MIDI reception buffer is cleared, and if key on remains it is turned off.
4 and 5 are not available during a Dump Request and 32 becomes "F7".
3
Table 1 (1) MIDI Parameter Change table ( Multi ) $F0, $43, $1n, $29, $00, sub_group, p_msb, p_lsb, v_msb, v_lsb, $F7 Note) n ; Device Number s ; parameter sub_group number p ; parameter number v ; parameter value [MULTI PARAMETERS] 1. COMMON s=0 PARAMETER reserved effect mode effect1 type effect2 type effect control1 parameter effect control1 add controller effect control2 parameter effect control2 add controller effect control2 min limit effect control2 max limit effect1 parameter1 effect1 parameter2 effect1 parameter3 effect1 parameter4 effect1 parameter5 effect1 parameter6 effect1 parameter7 effect1 parameter8 effect1 level-a effect1 level-b effect2 parameter1 effect2 parameter2 effect2 parameter3 effect2 parameter4 effect2 parameter5 effect2 parameter6 effect2 parameter7 effect2 parameter8 effect2 level-a effect2 level-b effect mix level effect balance out1 effect balance out2 effect control1 min limit effect control1 max limit effect lfo wave effect lfo speed effect lfo delay time effect insert 1b effect insert 2a BULK NUMBER 0 1 2 3 4 5 6 7 8 9 10 | | Not in order | | | | 33 34 35 36 | | Not in order | | | | 59 60 61 62 63 64 65 66 67 68 69 70 71 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 PARAM NUMBER DATA RANGE 0 0. . 2 0. . 90 0. . 90 0. . 31 0. . 124 0. . 31 0. . 124 0. . 100 0. . 100 0. . ???0. . 100 0. . 100 0. . 100 0. . 100 0. . 100 0. . 100 0. . 100 0. . 6 0. . 99 0. . 99 0. . 100 0. . 100 off, seri, para 0. . 90 0. . 90 off. . Ef_Ins2b 0. . 124 off. . Ef_Ins2b 0. . 124 0. . 100 0. . 100 ??? [. . . ] 0. . 100 0. . 100 0. . 100 0. . 100 0. . 100 0. . 100 0. . 100 tri. . 1tm 0. . 99 0. . 99 0. . 100 0. . 100
To be continued
DISP
4
PARAMETER effect insert 2b multi name top multi name | multi name | multi name | multi name | multi name | multi name | multi name bottom reserved reserved reserved reserved reserved reserved reserved reserved reserved reserved reserved reserved 2. off, seri, para 0. . 90 0. . 90 off. . LFO dly 0. . 124 off. . LFO dly 0. . 124 0. . 100 0. . 100 ??????
To be continued
DISP
8
PARAMETER effect2 parameter7 effect2 parameter8 effect2 level-a effect2 level-b effect mix level effect balance out1 reserved effect control1 min limit effect control1 max limit effect lfo wave effect lfo speed effect lfo delay time reserved voice name top voice name | voice name | voice name | voice name | voice name | voice name | voice name bottom wave card bank AWM_CARD ID# MC1 pmod range MC1 amod range MC1 fmod range MC1 cutoff range MC1 egbias range MC2 pmod range MC2 amod range MC2 fmod range MC2 cutoff range MC2 egbias range after touch pmod range after touch amod range after touch fmod range after touch cutoff range after touch egbias range after touch pitch bend range poly after touch switch pitch bend range reserved reserved volume low limit MC3 parameter MC3 parameter min limit MC3 parameter max limit MC4 parameter MC4 parameter min limit MC4 parameter max limit
BULK NUMBER | 59 60 61 62 63 64 65 66 67 68 69 70. . 72 73 74 75 76 77 78 79 80 81 82, 83 84 85 86 87, 88 89, 90 91 92 93 94, 95 96, 97 98 99 100 101, 102 103, 104 105, 106 107, 108 109
PARAM NUMBER 26 27 28 29 30 31 33 34 35 36 37 49 50 51 52 53 54 55 56 57 58 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77
DATA RANGE 0. . ??? [. . . ]