User manual YAMAHA YFP70E

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual YAMAHA YFP70E. We hope that this YAMAHA YFP70E user guide will be useful to you.

Lastmanuals help download the user guide YAMAHA YFP70E.


Mode d'emploi YAMAHA YFP70E
Download
Manual abstract: user guide YAMAHA YFP70E

Detailed instructions for use are in the User's Guide.

[. . . ] IMPORTANT: When connecting this product to accessories and/or another product use only high quality shielded cables. Cable/s supplied with this product MUST be used. Failure to follow instructions could void your FCC authorization to use this product in the USA. NOTE: This product has been tested and found to comply with the requirements listed in FCC Regulations, Part 15 for Class "B" digital devices. [. . . ] Press the [DOWN] button continuously decreases the group number by one (1). · Press the [UP] and [DOWN] button simultaneously to switch between the USER AREA PRESET AREA. · GROUP The 90 patches in each area are divided into 10 groups (0-9). · BANK Each group is divided into 3 banks (1-3). · PATCH Each bank contains 3 patches (1-3). 011 0. 11 · Patch Characteristics USER AREA GROUP 1 GROUP 0 BANK 1 PATCH 1 PATCH 2 PATCH 3 BANK 2 PATCH 1 PATCH 2 PATCH 3 BANK 3 PATCH 1 PATCH 2 PATCH 3 GROUP 9 PRESET AREA GROUP 1 GROUP 0 BANK 1 PATCH 1 PATCH 2 PATCH 3 BANK 2 PATCH 1 PATCH 2 PATCH 3 BANK 3 PATCH 1 PATCH 2 PATCH 3 GROUP 9 15 Using the DG-Stomp q Using the Foot Switch and the Bank Switch · Press a foot switch (1-3) to select the corresponding patch number 1-3 in the currently selected group/bank. * If the Foot Switch's function is set to "EFF" in the Utility mode, it will not be possible to select a patch using the Foot Switch. (See page 23) q Using MIDI Control MIDI program change data transmitted from an external MIDI device such as the YAMAHA MIDI Foot Controller MFC10, etc. can be used to select patches in the DG-Stomp. Use a MIDI cable to connect the MIDI IN jack on the DG-Stomp to the MIDI OUT jack on an external MIDI device. * Make sure to use a MIDI cable that conforms to the MIDI standard. Also, limit the length of the MIDI cable to 15 meters. Use of a long cable may result in trouble such as inferior performance of the device, etc. · Press and hold the BANK switch until the display and the foot switch lamp flashes then remove your foot. In this condition, the following procedure can be used. * Even if the Foot Switch function is set to "EFF" in the Utility Mode, this mode can be entered by stepping on the BANK switch. MIDI IN 1. Hold Foot Switch 1 for more than one second to switch between the USER AREA PRESET AREA. * The OUTPUT knob's setting is not stored with the patch data. Use the MASTER knob to set differences in volume for situations like backing, soloing, etc. * Data in the USER AREA (011-933) can be stored in an external MIDI device. Press the [UTILITY] button and set the amp select switch to the LEAD 1 position. After entering the Utility Mode, "F. S" will appear on the display and then the currently selected foot switch function will be displayed. · · PrG : Select a patch EFF : Switches the effect block ON/OFF 2. Use the [UP]/[DOWN] buttons to set the foot switch function to "EFF". Press the [UTILITY] button to return to the Play Mode. Press Foot Switches 1-3 to switch the corresponding effect block ON/OFF. * To change the Bank, Group or Area, press and hold the BANK switch until the display and the Foot Switch lamp flashes. ( page 16) This procedure can be used to store original patches and also used to rearrange the order of patches for use during live performance. 17 Using the DG-Stomp q Using the DG-Stomp Without Patches The [MANUAL] button lets you control the DG-Stomp when patches are not used. Press the [MANUAL] button to enter the Manual Mode (the lamp lights). In this mode, all knobs and effect buttons are set to their present condition. In the Manual Mode, changes to any knob or button can be performed directly. [. . . ] · GLb : The speaker simulator is always ON. · PrG : The speaker simulator is switched ON/ OFF according to the patch setting. · oFF : The speaker simulator is always OFF 27 Error Messages If an error occurs during operation, one of the following error message numbers will appear on the display. E1: MIDI Receive Buffer Full CAUSE: Too much MIDI data is being received by the DG amplifier at one time. SOLUTION: Try reducing the amount of data being sent or, break the data into smaller blocks. E2: Communication Error. CAUSE: An abnormality is detected during MIDI communications. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE YAMAHA YFP70E

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual YAMAHA YFP70E will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag