User manual ZANUSSI EFT622

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ZANUSSI EFT622. We hope that this ZANUSSI EFT622 user guide will be useful to you.

Lastmanuals help download the user guide ZANUSSI EFT622.


Mode d'emploi ZANUSSI EFT622
Download
Manual abstract: user guide ZANUSSI EFT622

Detailed instructions for use are in the User's Guide.

[. . . ] · Deep fat fryers must be continuously monitored during use: overheated oil can burst into flames. · The hood should not be used by children or persons not instructed in its correct use. · The appliance is not intended for use by young children or infirm persons without supervision. · Young children should be supervised to ensure that they do not play with the appliance. [. . . ] MAINTENANCE · Switch off or unplug the appliance from the mains supply before carrying out any maintenance work. · Clean and/or replace the Filters after the specified time period. · Clean the hood using a damp cloth and a neutral liquid detergent. 650 mm min. GB 3 CHARACTERISTICS GB 507 108 244 100 740 300 360 150 898 min. 1145 60 132 4 Components 15 14. 1 12a 7. 2. 1 14 9 11 Ref. 1 2 2. 1 2. 2 8a 8b 9 14 14. 1 15 Q. ty Product Components 1 Hood Body, complete with: Controls, Light, Blower, Filters 1 Telescopic Chimney comprising: 1 Upper Section 1 Lower Section 1 Right Air Outlet Grill 1 Left Air Outlet Grill 1 Reducer Flange ø 150-120 mm 1 Hood Body Air Outlet Extension Piece consisting of two Half Shells 2 Air Outlet Connection Extension 1 Air Outlet Connection 2. 1 2 8b 2. 2 12c 8a Ref. Q. ty Installation Components 7. 2. 1 2 Upper Chimney Section Fixing Brackets 11 6 Wall Plugs 12a 6 Screws 4, 2 x 44, 4 12c 4 Screws 2, 9 x 9, 5 Q. ty Documentation 1 Instruction Manual 11 12a 1 GB 5 INSTALLATION Wall drilling and bracket fixing 1÷2 11 12a 650 min. 116 116 323 Wall marking: · Draw a vertical line on the supporting wall up to the ceiling, or as high as practical, at the centre of the area in which the hood will be installed. · Draw a horizontal line at 650 mm above the hob. · Place bracket 7. 2. 1 on the wall as shown about 1-2 mm from the ceiling or upper limit aligning the centre (notch) with the vertical reference line. · Mark the wall at the centres of the holes in the bracket. If this is not the case, adjust the position by either reversing the connection extension pieces 14. 1 or by cutting the hood body extension 14 along one of the thinner section channels denoting the pre-fixed lengths, then reassemble as described previously. · The air outlet directional grills 8a - 8b must be fitted after the lower outlet duct has been installed. · Ensure that the activated charcoal filters have been inserted. 15 8b 14 14. 1 8a ELECTRICAL CONNECTION · Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm. Flue assembly Upper exhaust flue · Slightly widen the two sides of the upper flue and hook them behind the brackets 7. 2. 1, making sure that they are well seated. · Secure the sides to the brackets using the 4 screws 12c (2, 9 x 9, 5) supplied. Lower exhaust flue · Slightly widen the two sides of the flue and hook them between the upper flue and the wall, making sure that they are well seated. · Fix the lower part laterally to the hood body using the 2 screws 12c (2, 9 x 9, 5) supplied. · On the recirculation version, fit the directional grids 8a ­ 8b in their housings making sure that the directional symbols are towards the top and front of the hood. Also make sure that they are correctly inserted in the connection extension pieces 14. 1. 2 8b 2. 2 8a 7. 2. 1 12c 2. 1 12c GB 8 USE Control panel L S V1 V2 V3 L S V1 V2 V3 Light Led Motor Speed Intensive Switches the lighting system on and off. Switches the extractor motor on and off at low speed. [. . . ] Also make sure that they are correctly inserted in the connection extension pieces 14. 1. 2 8b 2. 2 8a 7. 2. 1 12c 2. 1 12c GB 8 USE Control panel L S V1 V2 V3 L S V1 V2 V3 Light Led Motor Speed Intensive Switches the lighting system on and off. Switches the extractor motor on and off at low speed. Used to provide a continuos and silent air change in the presence of light cooking vapours. Medium speed, suitable for most operating conditions given the optimum treated air flox/noise level ratio. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZANUSSI EFT622

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ZANUSSI EFT622 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag