Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ZANUSSI EGG685W. We hope that this ZANUSSI EGG685W user guide will be useful to you.
Lastmanuals help download the user guide ZANUSSI EGG685W.
Detailed instructions for use are in the User's Guide.
[. . . ] Gas hob
INSTRUCTION BOOKLET
Please read this instruction booklet before using the appliance
Mod. EGG 685
35670-3002
GB
Important Safety Information
You MUST read these warnings carefully before installing or using the hob. If you need assistance, contact our Customer Care Department on 08705 950950
Installation
l
Service
l
l
l l
l
This hob must be installed by qualified personnel, according to the manufacturers instructions and to the relevant British Standards. Any gas installation must be carried out by a registered CORGI installer. [. . . ] Estate Chelmsford Essex CM12 3AE Unit 14 Capitol Park Capitol Way Colindale London NW9 0EQ 194 Court Road Mottingham Eltham London SE9 4EW 284 Alma Road Enfield London EN3 7BB Unit B4 Imperial Business Estate West Mill Gravesend Kent DA11 0DL Unit 6C Elton Park Business Centre Hadleigh Road Ipswich IP2 0DD 16-17 Woodside Ind. Park Works Road Letchworth Herts SG6 1LA 2 - 4 Royal Lane Yiewsley West Drayton Middlesex UB7 8DL Reform Road Maidenhead Berkshire SL6 8BY 10 Island Farm Avenue West Molesey Surrey KT8 2UZ 9 Pipers Court Berkshire Drive Thatcham Berkshire RG19 4ER REDRUTH NORWICH 2b Trafalgar Street Norwich NR1 3HN Unit 1a The Summit Hanworth Road Sunbury on Thames TW16 5DB ASHFORD
SOUTH EAST
Unit 2 Bridge Road Business Centre Bridge Road Ashford Kent TN23 1BB Unit 1 Redfields Ind. Estate Church Crookham Fleet Hampshire GU13 0RD 21-25 Bridge Road Haywards Heath Sussex RH16 1UA
BOURNE
CHELMSFORD
FLEET
BRIDGNORTH
COLINDALE
HAYWARDS HEATH
GLOUCESTER
ELTHAM
HEREFORD
TONBRIDGE
ENFIELD
Unit 30 Deacon Trading Estate Morley Road Tonbridge TN9 1RA
HIGHAM FERRERS
GRAVESEND
SOUTH WEST
BARNSTAPLE Main Road Fremington Barnstaple North Devon EX31 2NT 63-65 Curzon Road Bournemouth Dorset BH1 4PW 6 Herswell Business Park Salmon Parade Bridgwater Somerset TA6 5PY 11 Eldon Way Eldonwall Trading Estate Bristol BS4 3QQ 266 Main Road Southbourne Emsworth PO10 8JL Unit 8 Enterprise Court Ryde Business Park Ryde Isle of Wight PO33 1DB Unit 2 Zealley Ind. Estate Kingsteignton Newton Abbot TQ12 3TD Unit 7D Pool Ind. Estate Druids Road Redruth Cornwall TR15 3RH
ILKESTON
LEICESTER
BOURNEMOUTH
LINCOLN
LETCHWORTH
BRIDGEWATER
BRISTOL
NEWCASTLE UNDER LYME
LONDON
EMSWORTH
MAIDENHEAD
REDDITCH
ISLE OF WIGHT
MOLESEY
TAMWORTH
NEWTON ABBOT
NEWBURY
WORCESTER
SUNBURY
8
Instructions for the Installer
Engineers technical data
Overall dimensions
Width: Depth: 580 mm. 510 mm.
Ignition HT Spark Spark Generator Spark Gap Semi-rapid Burner Heat Input
Ispra Control's BF 50046 230-240V 0. 6 YA T 120 Fixed
Cut out dimensions
Width: Depth: 550 mm. 470 mm.
1. 9 kW (6483 BTU/HR)
Supply connections
Gas: RC 1/2 inch (1/2 inch male) Rear right hand corner Electric: 230-240V 50Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse.
Rapid Burner Heat Input 2. 9 kW Natural Gas (9895 BTU/HR) 2. 7 kW L. P. G. (9212 BTU/HR) Auxiliary Burner Heat Input 1. 0 kW (3412 BTU/HR)
VALUE = 37. 78 MJ/m3 CHARACTERISTICS Ws - 50. 7 MJ/ m3
TYPE OF GAS
BURNER
RAPID (large) MAX MIN
SEMI-RAPID (medium) MAX MIN
AUXILIARY (small) MAX MIN
POSITION NOMINAL THERMAL POWER kW NOMINAL FLOW RATE m3/h NOZZLE REFERENCE 1/100 mm NOMINAL THERMAL POWER kW NOMINAL FLOW RATE g/h NOZZLE REFERENCE 1/100 mm
NATURAL GAS 20 mbar
2. 9 0. 276 119 2. 7 195 86
0. 65 0. 062 Adjust. 0. 65 46. 8 40
1. 9 0. 181 96 1. 9 137 71
0. 45 0. 043 Adjust. 0. 45 32. 4 32
1. 0 0. 095 70 1. 0 72 50
0. 33 0. 031 Adjust. 0. 33 23. 8 28
Burner Auxiliary Semi-rapid Rapid
VALUE = 49. 92 MJ/Kg
LPG GAS 28-30/37 mbar
Dia. Tap By-pass 1/100 mm 28 32 40
APPLIANCE CLASS: APPLIANCE CATEGORY:
3 II2H3+
APPLIANCE GAS SUPPLY: Natural gas G20 / 20mbar
Aeration adjustment none
9
Important safety requirements
This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition). Detailed recommendations are contained in the following British Standards Codes Of Practice: B. S. The hob should not be installed in a bed sitting room with a volume of less than 20 m3. If it is installed in a room of volume less than 5 m3 an air vent of effective area of 110 cm2 is required. If it is installed in a room of volume between 5 m3 and 10 m3 an air vent of effective area of 50 cm2 is required, while if the volume exceeds 11 m3 no air vent is required. However, if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5 m3 and 11 m3. If there are other fuel burning appliances in the same room, B. S. 5440 Part 2 Current Edition, should be consulted to determine the requisite air vent requirements.
FITTING THE GAS HOB WITHOUT A COOKER HOOD ABOVE
700 mm
400 mm
55
m
mm
50 m
400 mm
100
mm 50 m m
FO 0812
Location
The hob may be located in a kitchen, a kitchen/diner or bed sitting room, but not in a bathroom, shower room or garage. Before making the cut out in the worktop ensure that the edges of the hob that are to be near either a side or rear wall have a minimum distance of 55 mm. between the edge of the hob and the wall. The minimum distance combustible material can be fitted above the hob is 400 mm. [. . . ] Test leads from L to N in appliance terminal block. If meter reads «0» then there is a short circuit. If meter reads less than ¥ (infinity) there is a fault. NOTE - Should it be found that the fuse has failed but no fault is indicated - a detailed continuity check (i. e. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ZANUSSI EGG685W
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ZANUSSI EGG685W will begin.