[. . . ] Gas hobs
INSTRUCTION BOOKLET
Please read this instruction booklet before using the appliance
EHG 678
35670-2702
GB
Important Safety Information
You MUST read these warnings carefully before installing or using the hob. If you need assistance, contact our Customer Care Department on 08705 950950
Installation
l
Service
l
l
l l
l
This hob must be installed by qualified personnel, according to the manufacturers instructions and to the relevant British Standards. Any gas installation must be carried out by a registered CORGI installer. Remove all packaging before using the hob. [. . . ] * Products of Electrolux manufacture which are not marketed by Electrolux.
6
ELECTROLUX SERVICE FORCE
To contact your local Electrolux Service Force Centre telephone 08705 929 929 CHANNEL ISLANDS
GUERNSEY Guernsey Electricity PO Box 4 Vale, Guernsey Channel Islands Jersey Electricity Company PO Box 45 Queens Road St Helier Jersey Channel Islands JE4 8NY ISLE OF LEWIS (M69) ND Macleod 16 James Street Stornoway Isle of Lewis PA872QW 2-8 Wood Market Kelso Borders TD5 7AX Corsie Domestics 7 King Street Kirkwall Orkney KW15 1RE Hydro Electrical Inveralmond House Ruthervenfield Road Perth PH1 3AQ Graham Begg Unit 4 Airport Ind Estate Wick KW1 4QS Tait Electronic Systems Ltd. Holmsgarth Road Lerwick Shetland ZE1 0PW Bolts Shetland Ltd 26 North Road Lerwick Shetland ZE1 0PE Leask Electrical Harlsdale Symbister, Whalsay Shetland ZE2 9AA GRIMSBY (M42)
NORTH EAST
GATESHEAD (M39) Unit 356a Dukesway Court Dukesway Team Valley Gateshead NE11 0BH 15 Hainton Avenue Grimsby South Humberside DN32 9AS Unit 1 Boulevard Industrial Estate Hull HU3 4AY 64-66 Cross Gates Road Leeds LS15 7NN Unit 16 Gurney Wa y Aycliffe Ind Estate Newton Aycliffe DL5 6UJ Pennine House Roman Ridge Ind. Roman Ridge Road Sheffield S9 1GB
JERSEY
KELSO (M08) ORKNEY (M65)
PERTH
HULL (M41)
SCOTLAND
ABERDEEN (M05) AUCHTERMUCHY (M03) 54 Claremont Street Aberdeen AB10 6RA 33A Burnside Auchtermuchy Fife KY14 7AJ Unit 5 Block 2 Auchenraith Industrial Estate Rosendale Way Blantyre G72 0NJ 93 Irish Street Dumfries Scotland DG1 2PQ Briar Hill 7 Hill Street Dunoon Argyll PA23 7AL 20 Cunningham Road Clyde Estate Rutherglen, Glasgow, G73 1PP Unit 3B Smithton Indust. Works Road Letchworth Herts SG6 1LA 2/4 Royal Lane Yiewsley West Drayton Middlesex UB7 8DL Reform Road Maidenhead Berkshire SL6 8BY 10 Island Farm Avenue West Molesey Surrey KT8 2UZ 9 Pipers Court Berkshire Drive Thatcham Berkshire RG19 4ER Unit 6C Elton Park Business Centre Hadleigh Road Ipswich IP2 0DD 2b Trafalgar Street Norwich NR1 3HN Unit 1a The Summit Hanworth Road Hanworth Ind Estate Sunbury on Thames TW16 5D ASHFORD (M58)
SOUTH EAST
Unit 2 Bridge Road Business Estate Bridge Road Ashford Kent TN2 1BB Unit 1 Redfields Industrial Estate Church Crookham Fleet Hampshire GU13 0RD
CHELMSFORD (M47)
BOURNE (M44)
FLEET (M59)
COLINDALE (M53)
BRIDGNORTH (M72)
GLOUCESTER (M23) HEREFORD (M31)
ELTHAM (M78) ENFIELD (M49)
HAYWARDS HEATH 21-25 Bridge Road (M55) Haywards Heath Sussex RH16 1UA
SOUTH WEST
BARNSTAPLE (M30) Main Road Fremington Barnstaple North Devon EX31 2NT 63-65 Curzon Road Bournemouth Dorset BH1 4PW 6 Hamp Industrial Estate Bridgewater Somerset 11 Eldon Way Eldonwall Trading Bristol Av o n BS4 3QQ 266 Main Road Southboure Emsworth PO10 8JL Unit 8 Enterprise Court Ryde Business Park Ryde Isle of Wight PO33 1DB Unit 2 Zealley Industrial Estate Kingsteignton Newton Abbot S. Devon TQ12 3TD 16 Faraday Mill Cattledown Plymouth PL4 0ST Unit 7D Pool Industrial Estate Wilson Way, Redruth, Cornwall TR15 3QW
GRAVESEND (M57)
HIGHAM FERRERS (M51)
ILKESTON (M43)
BOURNEMOUTH (M26)
LEICESTER (M22)
BRIDGEWATER (M35)
LETCHWORTH (M50)
BRISTOL (M25)
LINCOLN (M40)
LONDON (M76)
EMSWORTH (M33)
NEWCASTLE UNDER LYME (M12)
MAIDENHEAD (M60)
ISLE OF WIGHT (M34)
REDDITCH (M20)
MOLESEY (M61)
NEWTON ABBOT (M29)
TAMWORTH (M19)
NEWBURY (M24)
WORCESTER (M73)
IPSWICH (M48)
PLYMOUTH (M32)
REDRUTH (M36)
NORWICH (M52) SUNBURY (M63)
8
Instructions for the Installer
Engineers technical data
OVERALL DIMENSIONS Width: Depth: 580 mm. SUPPLY CONNECTIONS Gas: RC 1/2 inch (1/2 inch male) Rear right hand corner Electric: 230-240V 50Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse.
CUT OUT DIMENSIONS Width: 560 mm. Thickness: 30 mm.
Ignition HT Spark Spark Generator Ispra Control's BF 50066 - 230-240V 0. 6 YA T 120 Spark Gap Fixed Rear Left Burner (semi-rapid) Heat Input 2. 0 kW (6824 BTU/HR) Front Left Burner (rapid) Heat Input 3. 0 kW Natural Gas (10236 BTU/HR) 2. 8 kW LPG (9554 BTU/HR) Rear Right Burner (semi-rapid) Heat Input 2. 0 kW (6824 BTU/HR) Front Right Burner (auxiliary) Heat Input 1. 0 kW (3412 BTU/HR)
TYPE OF GAS
BURNER Characteristics POSITION
VALUE = 37. 78 MJ/m3 Ws - 50. 7 MJ/ m3
RAPID (large) MAX MIN
SEMI-RAPID (medium) MAX MIN
AUXILIARY (small) MAX MIN
NATURAL GAS 20 mbar
NOMINAL THERMAL POWER kW NOMINAL FLOW RATE m3/h NOZZLE REFERENCE 1/100 mm NOMINAL THERMAL POWER kW NOMINAL FLOW RATE g/h
3. 0 0. 286 119
0. 65 0. 062 Adjust.
2. 0 0. 190 96
0. 45 0. 043 Adjust.
1. 0 0. 095 70
0. 33 0. 031 Adjust.
VALUE = 49. 92 MJ/Kg
LPG GAS 28-30/37 mbar
2. 8 202 86
0. 65 47 40
2. 0 144 71
0. 45 32 32
1. 0 72 50
0. 33 24 28
NOZZLE REFERENCE 1/100 mm
Burner Auxiliary Semi-rapid Rapid
Dia. Tap By-pass 1/100 mm 28 32 40
APPLIANCE CLASS: 3 APPLIANCE CATEGORY: II2H3+ APPLIANCE GAS SUPPLY: Natural gas G20 / 20mbar
Aeration adjustment none
9
Important safety requirements
This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition). Detailed recommendations are contained in the following British Standards Codes Of Practice: B. S. The hob should not be installed in a bed sitting room with a volume of less than 20 m3. If it is installed in a room of volume less than 5 m3 an air vent of effective area of 110 cm2 is required. If it is installed in a room of volume between 5 m3 and 10 m3 an air vent of effective area of 50 cm2 is required, while if the volume exceeds 11 m3 no air vent is required. However, if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5 m3 and 11 m3. If there are other fuel burning appliances in the same room, B. S. 5440 Part 2 Current Edition, should be consulted to determine the requisite air vent requirements.
FITTING THE GAS HOB WITHOUT A COOKER HOOD ABOVE
700 mm
400 mm
55 mm
50 m
m
400 mm
100
mm 50 m m
FO 0812
FITTING THE GAS HOB WITH A COOKER HOOD ABOVE
Location
The hob may be located in a kitchen, a kitchen/diner or bed sitting room, but not in a bathroom, shower room or garage. Before making the cut out in the worktop ensure that the edges of the hob that are to be near either a side or rear wall have a minimum distance of 55 mm. between the edge of the hob and the wall. The minimum distance combustible material can be fitted above the hob is 400 mm. must be allowed from the edges of the hob. The minimum distance combustible material can be fitted directly above the hob is 700 mm. must be left between the side edges of the hob and any adjacent cabinets or walls.
650 mm
600 mm
400 mm
50 m
55
m
mm
400 mm
100
mm 50 m m
FO 0813
Installation
IMPORTANT This hob must be installed by qualified personnel to the relevant British Standards. Any gas installation must be carried out by a registered CORGI installer. [. . . ] If meter reads «0» then there is a short circuit. If meter reads less than ¥ (infinity) there is a fault. NOTE - Should it be found that the fuse has failed but no fault is indicated - a detailed continuity check (i. e. by disconnecting and checking each component) is required to trace the faulty component. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ZANUSSI EHG678B
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.