Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ZANUSSI NH90EPN. We hope that this ZANUSSI NH90EPN user guide will be useful to you.
Lastmanuals help download the user guide ZANUSSI NH90EPN.
Detailed instructions for use are in the User's Guide.
[. . . ] 12 Filtro al carbone attivo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Illuminazione . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Pulizia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] · Never leave frying pans unattended during use as overheated fats and oils may catch fire. · If the room where the cooker hood is to be used contains a fuel burning appliance such as a central heating boiler then this must be of the room sealed or balanced flue type. If other types of flue or appliance are fitted en-sure that there is an adequate supply of air into the room. When the cooker hood is used in conjunction with other appliances supplied with energy other than electric, the negative pressure in the room must not exceed 0, 04 mbar to prevent fumes being drawn back into the room by the cooker hood.
COMPONENTS
The hood comprises the following (fig. 1 ): · No. 1 canopy C complete with controls, 2 lighting and ventilator unit · No. 1 telescopic chimney, comprising: No. 1 upper chimney element S V No. 1 lower chimney element I · No. 2 directional grills G A · No. 1 reduction flange Ø 150-120 A · No. 1 valve V (optional ) P1 · No. 1 recirculation spigot R · No. 1 deflector D · No. 2 additional side recirculation spigots P1 R · No. 1 additional recirculation spigot P · No. 1 bag containing: No. 2 brackets 2 to fix the chimney, D screws, rawl plugs and documents. · No. 1 splashback B (optional )
S G C I G
B
P
Fig. 1
14
GB
Installation instructions
· · · · · For easy installation, proceed as follows: Fix the wall brackets and Splashback Fix the canopy Connect the hood to the mains power supply and make sure that it works properly Set the hood for ducting or recirculation Fix the telescopic chimney
Fitting the wall brackets and Splashback
Please refer to (fig. 2a-b): · Draw a vertical line on the wall, from the centre of the cooking appliance up to the ceiling, using a marking pen. This is to ensure the correct vertical alignment of the various parts.
d = 1024 min
2 1
232
X
1
254
Fig. 2
· Fixing the wall brackets
20
item 2: a) Place one of the brackets 2 against the wall approximately 1 or 2 mm from the ceiling or from the top limit, aligning its centre (slot) with the vertical line. b) Mark the centres of two keyholes in the bracket on the wall. c) Rest the other bracket 2 against the wall, aligning it with the vertical line, at a distance X measured as shown in fig. 2 equal to the height of the upper chimney element S supplied with the hood. When 120 mm ducting is to be used it will be necessary to install the reduction flange item A on the air outlet (fig. 5). · When ducting the hood through the side air outlet from the lower chimney element I it is necessary to insert deflector D into spigot R to close off the opening that is not being used (fig. 6). · Connect the additional spigot P to the round fan outlet, pushing it downwards, and fit spigot R to additional spigot P in a similar manner (make sure that the two additional side recirculation spigots P1 are fitted to spigot R). Make sure that the height of the assembly R + P corresponds to the height of the chimney outlet (fig. · If the hood is supplied with the activated charcoal filters fitted, the filters should be removed (see paragraph on Maintenance ). · Recirculation fitting · The filtered air is returned to the room through the two plastic side grills G on the lower chimney element I . · Connect the additional spigot P to the round fan outlet, pushing it downwards, and fit spigot R to additional spigot P in a similar manner (make sure that the two additional side recirculation spigots P1 are fitted to spigot R). Make sure that the height of the assembly R + P corresponds to the height of the chimney outlet. (fig. 7). · Fit the activated charcoal filters inside the canopy (see paragraph on Maintenance ). Do not fit the venting grilles until after the chimney has been installed.
P1
P1
R D P
Fig. 6
P1
P1
R P G
A18 _714 _03
Fig. [. . . ] · To replace (fig. 12) Remove the two screws fixing the metal ring, extract the spotlight from the lamp holder by pulling gently. When replacing the spotlight, make sure that the two pins are correctly inserted in the housing on the lamp holder.
Fig. 12
Cleaning
When cleaning the hood: - Never use a wet cloth or sponge, or running water. - Never use thinners or products containing alcohol, as they might damage the paintwork. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ZANUSSI NH90EPN
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ZANUSSI NH90EPN will begin.