[. . . ] Where this appliance is installed in marine craft or in caravans, it shall not be used as a space heater. The work of installation must be carried out by competent and qualified installers according to the regulations in force. The appliance must be installed at a minimum distance of 50 cm. from curtains or other combustible material. [. . . ] It is never advisable to use wire pads, steel wool or acids for cleaning. For hobs having automatic ignition periodically carry out an accurate cleaning of the ignitor (ceramic or electrode) to avoid ignition difficulties, furthermore check that the baffle holes are not obstructed. Clean the plates with a damp cloth and lightly grease with vegetable oil or sewing machine oil whilst still warm. Periodic oiling of the taps must be carried out by qualified personnel who should also be contacted if a fault in the functioning of the appliance occurs.
INSTRUCTIONS FOR THE INSTALLER
ATTENTION: This appliance must be installed and used only in rooms which are permanently ventilated according to the regulations in force. The following instructions relating to installation and regulation must be carried out by qualified personnel. The appliance must be installed correctly in conformity with the rules and regulations in force. All interventions must be carried out with the appliance electrically disconnected. THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR ANY DAMAGES DERIVING FROM AN INSTALLATION WHICH DOES NOT CONFORM WITH THE REGULATIONS IN FORCE. SITE OF INSTALLATION For a good operation of the gas appliance it is indispensable that the air necessary for gas combustion can circulate in the room in a natural manner. (The installer must follow the regulations in force. )
q
The appliance must be installed at a minimum distance of 50 cm. from curtains or other combustible material.
7
CONNECTION TO THE GAS SUPPLY
Gas connection must be carried out in conformity with the regulations in force. The appliance leaves the factory tested and regulated for the type of gas indicated on the plate which is situated in the lower position near the gas connection tube. Ascertain that the type of gas with which the appliance will be supplied is the same as that indicated on the plate. If different carry out all the operations according to the indications cited in the paragraph "adaption to different types of gas". For a maximum output and minimum consumption ascertain that the pressure of the gas used has the values indicated in the table of "burner characteristics". If the pressure of the gas used is different (or variable) from that foreseen it is necessary to install a suitable pressure regulator on the inlet tube. The use of pressure regulators for liquid gas (GPL) is permitted as long as these conform to the regulations in force. The joint is mounted on the intake area of the pipe, fitted with a filleted nut GJ 1/2, between the sealing components as shown in Fig. Screw the parts without forcing, turn the joint in the direction required and then tighten everything. A) Intake pipe with nut B) Seal C) Adjustable joint
CONNECTION
Carry out the connection to the gas plant only by means of a rigid metallic tube conforming to the regulations in force. The joint for the entry of gas into the appliance is threaded GJ 1/2". Carry out the connection avoiding any type of stress on the appliance. [. . . ] 17
MINIMUM DISTANCE TO BE RESPECTED (in millimetres)
55
.
FO 0805 Fig. 19
In case of a right or left side having a height exceeding that of the hob, this should be situated at a minimum of 100mm from the top opening. Cupboards or extractor fans should be situated at a minimum of 650mm from the hob (Fig. 19).
14
650 mm
M
IN
TECHNICAL ASSISTANCE AND SPARE PARTS
Before leaving the factory this appliance was tested and controlled by expert and specialized personnel in order to give the best working results. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ZANUSSI PI44GW
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.