Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ZANUSSI ZGF643ICX. We hope that this ZANUSSI ZGF643ICX user guide will be useful to you.
Lastmanuals help download the user guide ZANUSSI ZGF643ICX.
Detailed instructions for use are in the User's Guide.
[. . . ] TABLE DE CUISSON GASKOOKPLAAT GASKOCHMULDE GAS HOB
ZGF 643
NOTICE D'UTILISATION GEBRUIKSAANWIJZING GEBRAUCHSANLEITUNG INSTRUCTION BOOKLET
BE
ENGLISH
For Your Safety
These warnings are provided in the interest of safety. You installing or using the appliance.
MUST
read them carefully before
It is most important that this instruction book should be retained with the appliance for future reference. Should the appliance be sold or transferred, always ensure that the book is left with the appliance in order that the new owner can get to know the functions of the appliance and the relevant warnings.
During Operation
· This appliance has been designed to be operated by adults and children under supervision. Young children MUST NOT be allowed to tamper with the controls or play near or with the oven. [. . . ] To ensure the good operation of the hob and its safety features, it is necessary that the taps are periodically lubricated. q The periodic lubrication of the taps must be carried out by qualified personnel, which you must refer to also in case of malfunctioning. Technical Data
Gas Burners Rating Rapid Burner (big) 3 kW (G20) - 2, 8 kW (G30-31) Auxiliary Burner (small) 1 kW Semirapid Burner (medium) Class 3 Appliance Category 2 kW II 2E+3+ Length Width 560 mm. Electric Supply HOB RECESS DIMENSIONS 230 V 50 Hz
Setting Natural Gas 20 mbar / G25 25 mbar Gas connection G 1/2"
4. Instruction for the Installer
q The side walls of the unit in which the hob is going to be installed, must not exceed the height of the working top. q Avoid installing the appliance in the proximity of inflammable materials (e. g. q The following instructions about installation and maintenance must be carried out by qualified personnel in compliance with the regulation in force. The regulation to be applied for this type of installation is NBN D 5I. 003 : "Installations functioning with combustible gas lighter than air". q The appliance must be electrically disconnected before all interventions. If any electric supply to the appliance is required to carry out the work, ensure all the necessary precautions are followed.
GAS CONNECTION
It is indispensible that the connection to the gas mains are carried out by means of an AGB tap. Choose fixed connections or use a flexible pipe in AGB (stainless steel). If using flexible metallic pipes, be careful they do not come in contact with mobile parts or they are not squeezed. Use the same attention when the hob is combinated with an oven. This hob can be operated by Slochteren gas (G25) with a nominal pressure of 25 mbar or by natural gas with nominal pressure of 20 mbar. No regulation is required for use by these two types of gas. Before fitting the appliance ensure that the installation has the correct voltage for the appliance. At full capacity, the drop in pressure must not exceed 5%. Such a drop in pressure is caused by the following parameters: maximum capacity of meter; diameter and lenght of the tube in front and behind the meter; section of transit of variuos tubes positioned on the circuit; diameter of eventual connections.
A) Ramp with ending nut B) Seal C) Adjustable connection
IMPORTANT - To ensure a correct operation, a saving of energy and the long-life of the appliance, the voltage pressure of the appliance must correspond to the recommended values. The adjustable connection is fixed to the comprehensive ramp by means of a threaded nut GJ 1/2". Interpose the sealing between the components as shown in fig. Screw the parts without forcing, adjust the connection in the required direction and tighten everything. IMPORTANT - When the final connection has been made, it is essential that a thorough leak test is carried out on the hob and installation. [. . . ] 17
480
30
60
a b
20 min
380 140
FO 2044
FO 2043
a) Removable panel b) Space possibly useful for connections
Fig. 19
50 cm 2
120 cm 2
360 cm 2
FO 2041 FO 2042
180 cm 2
Fig. 21
550 min.
FO 0198
560 min.
FO 2240
650 min
591
30
41
GUARANTEE - SPARE PARTS
When calling for repairs during the period of guarantee ofthe appliance, the original invoice or receipt must be shown or sent together with the appliance to be repaired. General conditions of guarantee 1 The manufacturer guarantees the appliance indicated on the relative invoice for a period of one year from the date of purchase. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ZANUSSI ZGF643ICX
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ZANUSSI ZGF643ICX will begin.