[. . . ] Children should be kept away until it has cooled. Children can also injure themselves by pulling pans or pots off the hob.
q
Service
q
q
This appliance should only be repaired or serviced by an authorised Service Engineer and only genuine approved spare parts should be used.
During Use
q
This appliance is intended for domestic cooking only. It is not designed for commercial or industrial purposes. When in use a gas cooking appliance will produce heat and moisture in the room in which it has been installed. [. . . ] Wash the burners taps and crowns using hot soapy water, and remove marks with a mild paste cleaner. A well moistened soap impregnated steel wool pad can be used with caution, if the marks are particularly difficult to remove. After cleaning, be sure to wipe dry with a soft cloth.
Fig. 2
7
Something Not Working?
If the appliance is not working correctly, please carry out the following checks before contacting your local Service Centre.
SYMPTOM s There is no spark when lighting the gas
SOLUTION x Check that the unit is plugged in and the electrical supply is switched on x Check the mains fuse has not blown x Check the burner cap and crown have been replaced correctly, e. g. after cleaning.
s The gas ring burns unevenly
x Check the main jet is not blocked and the burner crown is clear of food particles. x Check the burner cap and crown have been replaced correctly, e. g. after cleaning.
If after all these checks, your appliance still does not operate correctly, contact your local Service Centre.
8
Instructions for the Installer
Engineer technical data
OVERALL DIMENSIONS Width: Depth: Height: Weight: 680 mm. 12 Kg.
Supply Connections
Gas: RC 1/2 inch (1/2 inch male) Rear right hand corner Electric: 230-V 50Hz supply, 3 core flexible cable with non rewireable plug. Appliance Gas supply: LPG 30 mbar
CUT OUT DIMENSIONS Width: 560 mm. Appliance Class: 3 Appliance category: I 3
Burner
Nominal Power kW kCal/h 814 1368 2095
LPG (Butane "A") Nozzle 50 65 80 g/h 75 126 193
Diameter Tap. By-Pass
Tap colour
Feeding Pressure mbar (*)
Auxiliary (dia. 90 mm. )
0, 95 1, 60 2, 45
28 35 45
Red/Yellow Brown/Black Blue/Yellow 30
(*) 1 mbar = 10 mm. water coloumn.
9
Installation
IMPORTANT This appliance must be installed by qualified personnel. The manufacturer will not accept liability, should the above instructions or any of the other safety instructions incorporated in this book be ignored.
Gas Connection
On the end of the shaft (A) , which includes the GJ 1/ 2" threaded elbow, an adjustable joint is fixed so that the washer (B) is fitted between the components as shown in the diagram. A drop of paint at both edges of the "L" joint (C) will evidence that the good seal of the connection has been tested in the factory. Before connecting the gas supply pipe to the joint (C), the installer will ensure that the paint drop is unbroken and the "L" connector has not been moved by the vibrations during handling and transportation. When the final connection has been made, it is essential that a thorough leak test is carried out on the hob and installation. Ensure that the main connection pipe does not exert any strain on the hob.
FO 1010
A) End of shaft with nut B) Washer C) Adjustable joint
Cut Out Size
The dimensions of the cut-out are given in the diagram.
Rectangular cut-out size for hob
in. [. . . ] F: Removal of Ignitor Switch (Isolate Electric Supply) 1. Remove the fixing nut from the switch and remove tab connections. Reassemble in reverse order and check with wiring diagram for correct reconnection.
Technical Maintenance
Check at regular intervals the condition and serviceability of the gas connection hose and pressure regulator, if any is fitted; in case of malfunction, do not repair but replace the whole faulty part. To ensure a smooth and safe operation, it is necessary to periodically grease the gas taps. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ZANUSSI ZGF759ICX
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.