User manual ZANUSSI ZGG642CX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ZANUSSI ZGG642CX. We hope that this ZANUSSI ZGG642CX user guide will be useful to you.

Lastmanuals help download the user guide ZANUSSI ZGG642CX.


Mode d'emploi ZANUSSI ZGG642CX
Download
Manual abstract: user guide ZANUSSI ZGG642CX

Detailed instructions for use are in the User's Guide.

[. . . ] GAS HOB ZGG 642 INSTRUCTION BOOKLET Please read this instruction booklet before using the appliance GB Important Safety Information You MUST read these warnings carefully before installing or using the hob. If you need assistance, contact our Customer Care Department on 08705 727 727. Installation · This appliance must be installed and serviced by a competent person as stated in the Gas Safety (Installation and Use) Regulations Current Editions and the IEE Wiring Regulations. Remove all packaging before using the hob. Ensure that the gas and electrical supply complies with the type stated on the rating plate, located near the gas supply pipe. [. . . ] Rapid Burner Heat Input 2. 9 kW Natural Gas (9895 BTU/HR) 2. 7 kW L. P. G. (9212 BTU/HR) Semi-rapid Burner Heat Input Auxiliary Burner Heat Input 1. 9 kW (6483 BTU/HR) CUT OUT DIMENSIONS Width: Depth: 550 mm. 1. 0 kW (3412 BTU/HR) SUPPLY CONNECTIONS Gas: RC 1/2 inch (1/2 inch male) Rear right hand corner Electric: 230 V 50 Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse. VALUE = 37. 78 MJ/m3 CHARACTERISTICS Ws - 50. 7 MJ/ m3 TYPE OF GAS BURNER RAPID (large) MAX MIN SEMI-RAPID (medium) MAX MIN AUXILIARY (small) MAX MIN POSITION NOMINAL THERMAL POWER kW NOMINAL FLOW RATE m3/h NOZZLE REFERENCE 1/100 mm NOMINAL THERMAL POWER kW NOMINAL FLOW RATE g/h NOZZLE REFERENCE 1/100 mm NATURAL GAS 20 mbar 2. 9 0. 65 1. 9 0. 45 1. 0 0. 33 0. 276 119 0. 062 Adjust. 0. 181 96 0. 043 Adjust. 0. 095 70 0. 031 Adjust. VALUE = 49. 92 MJ/Kg LPG GAS 28-30/37 mbar 2. 7 0. 65 1. 9 0. 45 1. 0 0. 33 195 86 46. 8 40 137 71 32. 4 32 72 50 23. 8 28 Burner Auxiliary Semi-rapid Rapid Dia. Tap By-pass 1/100 mm 28 32 40 APPLIANCE CLASS: 3 APPLIANCE CATEGORY: II2H3+ APPLIANCE GAS SUPPLY: Natural gas G20 / 20mbar Aeration adjustment none 7 Important safety requirements This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition). Detailed recommendations are contained in the following British Standards Codes Of Practice: B. S. 6891 Current Editions. Location The hob may be located in a kitchen, a kitchen/diner or bed sitting room, but not in a bathroom, shower room or garage. Before making the cut out in the worktop ensure that the edges of the hob that are to be near either a side or rear wall have a minimum distance of 55 mm. between the edge of the hob and the wall. The minimum distance combustible material can be fitted above the hob is 400 mm. must be allowed from the edges of the hob. The minimum distance combustible material can be fitted directly above the hob is 700 mm. must be left between the side edges of the hob and any adjacent cabinets or walls. Provision for Ventilation The hob should not be installed in a bed sitting room with a volume of less than 20 m3. If it is installed in a room of volume less than 5 m3 an air vent of effective area of 110 cm2 is required. If it is installed in a room of volume between 5 m3 and 10 m3 an air vent of effective area of 50 cm2 is required, while if the volume exceeds 11 m3 no air vent is required. However, if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5 m3 and 11 m3. If there are other fuel burning appliances in the same room, B. S. 5440 Part 2 Current Edition, should be consulted to determine the requisite air vent requirements. FITTING THE GAS HOB WITHOUT A COOKER HOOD ABOVE FITTING THE GAS HOB WITH A COOKER HOOD ABOVE 600 mm 700 mm 650 mm 400 mm 400 mm 50 m 55 m mm 400 mm 100 mm 50 m 55 m mm 400 mm 100 mm 50 m m 50 m m FO 0812 FO 0813 8 Installation IMPORTANT This hob must be installed by a competent and qualified person only. The manufacturer will not accept liability, should the above instructions or any of the other safety instructions incorporated in this book be ignored. Gas Connection Connection to the gas supply should be with either rigid or semi-rigid pipe, i. e. The connection should be suitable for connecting to RC 1/2 (1/2 BSP male thread). When the final connection has been made, it is essential that a thorough leak test is carried out on the hob and installation. Ensure that the main connection pipe does not exert any strain on the hob. 2) Place the sealing gasket all around the glass top edge as shown in diagram 4. [. . . ] Pressure Testing Remove left hand pan support and front left burner cap and crown. Turn on the burner gas supply and ignite another burner. The pressure reading should be nominally 20mbar and must be between 17 mbar and 25mbar. Turn off the burner supplies. Minimum adjustment screw Conversion from Natural Gas to LPG It is important to note that this model is designed for use with natural gas but can be converted for use with butane or propane gas providing the correct injectors are fitted. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZANUSSI ZGG642CX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ZANUSSI ZGG642CX will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag