Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ZANUSSI ZGM782ITX. We hope that this ZANUSSI ZGM782ITX user guide will be useful to you.
Lastmanuals help download the user guide ZANUSSI ZGM782ITX.
Detailed instructions for use are in the User's Guide.
[. . . ] GAS HOB ZGM 782 ITX
INSTRUCTION BOOKLET
Please read this instruction booklet before using the appliance
GB
IE
Important Safety Information
You MUST read these warnings carefully before installing or using the hob. If you need assistance, contact our Customer Care Department on 08705 727727
Installation
This appliance must be installed and serviced by a competent person as stated in the Gas Safety (Installation and Use) Regulations Current Editions and the IEE Wiring Regulations. For appliances installed in the Republic of Ireland please refer to NSAI-Domestic Gas Installations I. S. 813 Current Editions and the ETCI Rules for Electrical Installations. Remove all packaging before using the hob. [. . . ] SYMPTOM There is no spark when lighting the gas SOLUTION Check that the unit is plugged in and the electrical supply is switched on Check that the RCCB has not tripped (if fitted) Check the mains fuse has not blown Check the burner cap and crown have been replaced correctly, e. g. The gas ring burns unevenly Check the main jet is not blocked and the burner crown is clear of food particles. Check the burner cap and crown have been replaced correctly, e. g. If after all these checks, your hob still does not operate correctly, contact your local Service Force Centre. Please note that it will be necessary to provide proof of purchase for any in-guarantee service calls.
In-guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a mechanical or electrical breakdown.
7
Instructions for the Installer
Engineers technical data
OVERALL DIMENSIONS Width: Depth: 680 mm 510 mm Rear Left Burner (semi rapid) Heat Input 2. 0 kW (6824 BTU/HR) Front Left Burner (auxiliary) Heat Input 1. 0 kW (3413 BTU/HR) Rear Right Burner (semi rapid) Heat Input 2. 0 kW (6824 BTU/HR) Front Right Burner (rapid) Heat Input 3. 0 kW (10236 BTU/HR) Central Burner (Ultra-rapid Triple-crown) Heat Input 4. 0 kW (13652 BTU/HR)
CUT OUT DIMENSIONS Width: Depth: 560 mm 480 mm
SUPPLY CONNECTIONS Gas: R 1/2 inch (1/2 inch male) Rear right hand corner Electric: 230 V 50 Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse.
VALUE = 37. 78 MJ/m3 CHARACTERISTICS Ws - 50. 7 MJ/ m3
TYPE OF GAS
BURNER
RAPID (large) MAX MIN
SEMI-RAPID (medium) MAX MIN
AUXILIARY (small) MAX MIN
ULTRA-RAPID (triple-crown) MAX MIN
POSITION NOMINAL THERMAL POWER kW NOMINAL FLOW RATE m3/h NOZZLE REFERENCE 1/100 mm NOMINAL THERMAL POWER kW NOMINAL FLOW RATE g/h NOZZLE REFERENCE 1/100 mm
NATURAL GAS 20 mbar
3. 0
0. 75
2. 0
0. 45
1. 0
0. 33
4. 0
1. 2
0. 286 119
0. 062 Adjust.
0. 190 96
0. 043 Adjust.
0. 095 70
0. 031 Adjust.
0. 381 146
0. 114 Adjust.
VALUE = 49. 92 MJ/Kg
LPG GAS 28-30/37 mbar
2. 8
0. 75
2. 0
0. 45
1. 0
0. 33
4. 0
1. 2
202 86
47 42
144 71
32 32
72 50
24 28
288 98
86 56
Burner Auxiliary Semi-rapid Rapid Ultra-rapid
Dia. Tap By-pass 1/100 mm 28 32 42 56
APPLIANCE CLASS : 3 APPLIANCE CATEGORY: II2H3+ APPLIANCE GAS SUPPLY: Natural gas G20 / 20mbar
Aeration adjustment none
8
Important safety requirements
This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition). For appliances installed in the Republic of Ireland please refer to NSAI- Domestic Gas Installation I. S. 813 Current Editions and the ETCI Rules for Electrical Installations.
Provision for ventilation
Detailed recommendations are contained in the following British Standards Codes Of Practice: B. S. The hob should not be installed in a bed sitting room with a volume of less than 20 m3. If it is installed in a room of volume less than 5 m3 an air vent of effective area of 100 cm2 is required. If it is installed in a room of volume between 5 m3 and 10 m3 an air vent of effective area of 50 cm2 is required, while if the volume exceeds 11 m3 no air vent is required. However, if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5 m3 and 11 m3. If there are other fuel burning appliances in the same room, B. S. 5440 Part 2 Current Edition, should be consulted to determine the requisite air vent requirements. For appliances installed in the Republic of Ireland please refer to the NSAI- Domestic Gas Installation I. S. It is also recommended to carry out the electrical connection to the hob as shown in diagrams 1 and 2.
Building over a kitchen unit with door
Proper arrangements must be taken in designing the furniture unit, in order to avoid any contact with the bottom of the hob which can be heated when it is operated. The recommended solution is shown in diagram 3. The panel fitted under the hob ("a") should be easily removable to allow easy access if technical assistance is needed. The space behind the kitchen unit ("b") can be used for connections.
Dimensions are given in mm.
1
2
3
FO 2563
FO 2564
FO 2044
Fitting the Hob into the worktop
Carry out the building in of the hob as follows: · put the seals supplied with the hob, on the edges of the cut out: place them at 8 mm from the front and rear edges of the cut out and at 50 mm from the side edges, as shown in the diagram, taking care that the seals meet without overlapping; · place the hob in the cut out, taking care that it is centred; · fix the hob with the relevant fixing clamps and screws, as shown in the diagram. When the screws have been tightened, the excess seal can be removed. The edge of the hob forms a double seal which prevents the ingress of liquids.
11
a Electrical connections
Any electrical work required to install this hob should be carried out by a qualified electrician or competent person, in accordance with the current regulations. The manufacturer declines any liability should these safety measures not be observed. [. . . ] Pressure Testing Remove left hand pan support and front left burner cap and crown. Turn on the burner gas supply and ignite another burner. The pressure reading should be nominally 20mbar and must be between 17 mbar and 25mbar. Turn off the burner supplies.
Minimum adjustment screw
Conversion from Natural Gas to LPG
IMPORTANT The replacement/conversion of the gas hob should only be undertaken by a competent person. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ZANUSSI ZGM782ITX
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ZANUSSI ZGM782ITX will begin.