User manual ZANUSSI ZHC9244X

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ZANUSSI ZHC9244X. We hope that this ZANUSSI ZHC9244X user guide will be useful to you.

Lastmanuals help download the user guide ZANUSSI ZHC9244X.


Mode d'emploi ZANUSSI ZHC9244X
Download
Manual abstract: user guide ZANUSSI ZHC9244X

Detailed instructions for use are in the User's Guide.

[. . . ] 6 Montaggio delle staffe di supporto . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Montaggio del corpo cappa (fig. 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Connessione elettrica e controllo funzionale . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Connessione aspirante o filtrante . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] When the cooker hood is used in conjunction with other appliances supplied with energy other than electric, the negative pressure in the room must not exceed 0, 04 mbar to prevent fumes being drawn back into the room by the cooker hood. Components The cooker hood is made up of the following components (fig 1): · n. 1 hood canopy C complete with controls, lighting and fan motor. 1 telescopic chimney stack formed by: n. 1 U-shaped lower section item I · n. 2 recirculation venting grilles item G (special versions only) · n. 1 reduction flange Ø 150-120 A · n. 1 recirculation spigot item R · n. 1 deflector D (special versions only) · n. 1 additional recirculation spigot P (special versions only) · n. 2 wall brackets 1 to fix the canopy hood n. 2 wall brackets 2 to fix the chimney, rawl plugs, screws, and documentation · n. · Connect the cooker hood to the mains via a double pole switch which has 3 mm clearance between the contacts. · Once the electrical connection has been completed, check that worktop illumination, motor and speed work properly. Ducting or Recirculation fitting · Ducting fitting a) The cooker hood can be ducted to the outside using either rigid or flexible fire retardant ducting of 120 or 150 mm. When 120 mm ducting is to be used it will be necessary to install the reduction flange item A on the air outlet (fig. 4). b) The installer should provide suitable ducting and sealing material for the installation. c) The cooker hood can also be ducted to the outside through one of the rectangular openings located in either side of the lower section of the chimney stack (item I). In this case the deflector (item D) should be fitted into the spigot (item R) to close the aperture which is notused (fig. 5). d) If the hood is provided with the charcoal filters fitted, the filters should be removed. · Recirculation fitting a) The filtered air is returned to the room through the two side grilles on U-shaped lower section I, which are either formed in the metal itself (bottom position fig. 6), or as a plastic insert, and have two different heights to deal with different needs (bottom position fig. 6, top position fig. 7). b) Lower position (fig. 6): fit the recirculation spigot item R into the round outlet on top of the canopy while pressing down on the spigot until it snaps into position. c) Upper position (fig. 7): fit the additional spigot, item P, into the round outlet on top of the canopy while pressing down on the spigot until it snaps into position. Then fit the recirculation spigot R into the top of the spigot, item P, and install the charcoal filters inside the canopy. [. . . ] · Replacement a) To remove the filter for subsequent replacement first open the metal grille panel (fig. 13a) by pressing back on the two slide catches towards the rear wall which will allow the grille panel to open and hinge downward from the rear. b) To remove the metal grille panel slide the right hand edge forward until the hinge pin comes away from the recess in the side casing as illustrated in fig 13b. c) The filter is easily removed from the grille by pushing the wire clips to one side and removing as illustrated in fig. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZANUSSI ZHC9244X

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ZANUSSI ZHC9244X will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag