[. . . ] The symbols below help you to find things more easily: Safety precautions Warnings and information at this symbol serve safety for you and your appliance.
Hints, useful information
Environmental information
Symbol for ideas At this symbol ideas can be found according to food and its storing. The symbol on the product or on its packaging indicates that this product may not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. [. . . ] During this the automatic defrosting is ineffective.
Maintenance
Defrosting
Bleeding part of the moisture of cooling chambers in form of frost and ice goes with the operation of the appliance. Thick frost and ice has an insulating effect, so it reduces cooling efficiency as the temperature increases in the cooling chambers and they need more energy. At this type of appliance defrosting the cooling plate of the refrigerator is automatic without any external intervention. The thermostatic control interrupts the operation of compressor at regular intervals for more or less time during this cooling is interrupted - the temperature of the cooling plate goes above 0 °C due to interior heating load of the compartment, so defrosting occurs. When the surface temperature of the cooling plate has reached +3 +4 °C the thermostatic control restarts operation of the system. Melting water flows through defrost water outlet leaded through the back into the evaporative tray maintained on the top of compressor and evaporates due to its warmth. Check and clean the outlet of melting water coming during defrosting regularly - a label inside the appliance warns you for this. If it is clogged the melting water gathered can cause earlier failure as it can go to the insulating of the appliance.
49
GB
Remaining small ice and frost stains on back plate of the refrigerator after defrosting period is not abnormal. The freezer can not be equipped with automatic defrosting set since the deep-frozen and frozen foods do not endure melting temperature. When small frost and ice occurs scrape off and remove frost and ice coating with the supplied plastic scraper. The tray in figure is not a piece of accessories to the appliance!Thermostatic control can be set wrongly. The door does not close tightly or it is not shut properly. Products in big quantity to be frozen were put in. Products to be frozen are placed too closely to each other. Water flows at the back plate of the refrigerator. During automatic defrosting frost melts on the back plate. The outlet of the chamber can be clogged up. Products placed in can prevent water from flowing into the collector. The melting water outlet flows not into the evaporative tray above the compressor. Doors are not shut properly or do not close tightly. The thermostatic control can be set wrongly. [. . . ] Applying the guarantee is subject to the consumer providing proof of purchase showing the purchase and/or delivery date. The guarantee will not apply if damage caused to delicate parts, such as glass (vitreous ceramic), synthetic materials and rubber, is the result of inappropriate use. The guarantee cannot be called on for minor faults that do not affect the value or the overall reliability of the appliance. The statutory warranty does not apply when defects are caused by: a chemical or electrochemical reaction caused by water, abnormal environmental conditions in general, unsuitable operating conditions, contact with harsh substances. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ZANUSSI ZRC404CS
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.