User manual ZEISS AXIOVERT 135

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ZEISS AXIOVERT 135. We hope that this ZEISS AXIOVERT 135 user guide will be useful to you.

Lastmanuals help download the user guide ZEISS AXIOVERT 135.


Mode d'emploi ZEISS AXIOVERT 135
Download
Manual abstract: user guide ZEISS AXIOVERT 135

Detailed instructions for use are in the User's Guide.

[. . . ] It is not permitted to pass on or copy this document, or to use or forward its contents unless prior consent has been provided. If this regulation is not observed, damages will be claimed. All patenting rights are reserved. For further details, please contact: Carl Zeiss Microscopy D 07740 Jena Phone: ++49 3641 64 16 16 Telefax: ++49 3641 64 31 44 E mail: micro@zeiss. de Internet: www. zeiss. de/micro 3 Subject to change B 40 042 e 09/99 Contents Notes on the safe operation of the instrument . Automatic balancing of focusing speed and focus position . [. . . ] 40x; lever for rapid change of fixed front lens; with iris diaphragm for aperture adjustment for objectives w5x 445340 0000 000 Achromatic dual condenser 0. 5 mot. Condenser holder Z like 445340 0000 000, but motorized 445341 0000 000 to allow mounting of: ultracondenser 1. 2/1. 4 or dry darkfield condenser 0. 8/0. 95 445323 0000 000 Ultra condenser 1. 2/1. 4 special condenser for darkfield, high magnification 465500 0000 000 and apertue suitable for objectives with aperture (replaces 0. 75 . . . 1. 0 445315 0000 000) Dry darkfield con denser 0. 8/0. 95 special condenser for darkfield, medium magnifi cation and aperture special condenser for darkfield, medium magnification and aperture, suitable for objectives with aperture 0. 6 . . . 0. 75 for unilateral darkfield illumination at low magnifi cations between 1. 25x and 10x; switching to brightfield is possible 465505 0000 000 Darkfield illuminator 445314 0000 000 Condenser for photometry insert suitable ICS objective in condenser carrier for photometry 452126 0000 000 in preparation 12 11 B 40 042 e 09/99 53 Microscope Components Condenser carrier (Fig. 33) The condenser you selected is contained in the condenser car rier. These are its control elements: 1 2 3 o 8 4 o o 1 2 3 4 5 6 7 8 Fig. 33 7 6 Condenser carrier Height adjustment Clamping screw for the condenser Strain fr ee illumination optics Orientation notch Centering screw Stop for height adjustment Stop screw for height adjustment Condenser carrier 5 Height adjustment on both sides (max. The ease of motion is factory adjusted (to be changed only by the service staff). Clamping screw (3) for the condenser (used only for con denser exchange using SW 3 key). Two centering screws (6) for the condenser. These are used to center the luminous field diaphragm image for the setting of KÖHLER illumination. Changing the DIC prisms in the universal condenser (Fig. 36) The positions of the DIC prisms are marked with I, II, III. 1 1 2 3 5 4 1 2 3 4 5 Fig. 36 Cover on the underside DIC prism Prism mount Double function tool Groove Changing the DIC prism To loosen the cover on the condenser underside (1), loosen both grub screws using SW 2 screwdriver and remove the cover. Position turret disk with DIC prism to be changed in the exchange opening and hold it on the knurled ring, since no click stop is effective in this position. Unscrew retainer ring using the so called double function tool (4). Screw threaded side (4) of the tool into the prism mount (3) and then pull out the DIC prism. Remove the DIC prism (2) from the tool and screw on the new, required prism. Installation of the DIC prism is made in reverse order. Make sure that the DIC prism is oriented correctly (groove (5) must engage in the pinion of the mount). Make sure that the knurled ring of the turret disk is labeled correctly. 12 11 B 40 042 e 09/99 55 Microscope Components Achromatic aplanatic condenser 1. 4 The achromatic aplanatic condenser 1. 4 is equipped with fixed front lens and turret disk. The turret disk contains 6 positions and accepts max. [. . . ] 11 Communication via CAN, Communication via RS 232, . 34 Height adjustment of removable stage carrier, . 14 Compartment for insertion of auxiliary objects, . 15 Compartment for insertion of compensators, . [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZEISS AXIOVERT 135

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ZEISS AXIOVERT 135 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag