User manual ZIBRO R 45 C

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ZIBRO R 45 C. We hope that this ZIBRO R 45 C user guide will be useful to you.

Lastmanuals help download the user guide ZIBRO R 45 C.


Mode d'emploi ZIBRO R 45 C
Download
Manual abstract: user guide ZIBRO R 45 C

Detailed instructions for use are in the User's Guide.

[. . . ] This appliance comes with a 48-month manufacturer's warranty on all defects in materials or workmanship. We wish you much warmth and comfort from your Zibro. Yours sincerely, PVG International b. v. Customer Service Department 1 READ THE DIRECTIONS FOR USE FIRST. 2 IN CASE OF ANY DOUBT, CONTACT YOUR ZIBRO DEALER. 3 BEFORE YOU START READING, FOLD OUT THE LAST PAGE. 4 50 GENERAL DIRECTIONS FOR USE Below you will find the main steps to be taken for using your heater. For more details, please refer to the MANUAL (pages 53 ff. ). MAIN COMPONENTS OFF - button (for emergency stop) Knurled wick adjustment knob 1 2 Remove all packaging materials (refer to Section A, Fig. A). Fill the removable tank and wait 30 minutes before you ignite the heater (refer to Section B, Fig. [. . . ] The page opposite the folding page shows the minimum and maximum permissible burning heights of the flame (Fig. The flame can be slightly adjusted with the knurled wick adjustment knob (Fig. L). M If the flame remains low after the adjustment, the wick height must be adjusted (refer to Section F). Too low a flame may also be caused by: insufficient fuel poor fuel quality insufficient ventilation wastage of the wick (fill the tank) (contact your dealer) (leave window or door ajar) (contact your dealer or replace the wick, refer to section M) This heater is fitted with a safety system that ensures that it switches off if you lift the exchange tank out of the heater. To switch the heater on again, put the exchange tank back and follow the steps in chapter C. E SWITCHING OFF THE HEATER Let the heater burn at its lowest setting for approximately one minute. The flame will extinguish after a little while (Fig. M). F ADJUSTING THE WICK HEIGHT After a period of time the combustion may no longer be high enough (Section D). In that case you can adjust the wick height to improve the flame. To do this, the heater must have been switched off. Follow the procedure below: 1 Push the OFF - button (Fig. M). 4 55 N 2 Pull the knurled wick adjustment knob off the heater, so the wick height lock will be visible. 3 Take the plastic collar between your thumb and index finger and pull it out. The lower reservoir is contaminated by water. The wick has hardened on the upper side. Burn the heater until all fuel is used (Section H). You are using fuel which is past its `use by' date. Start every heating season with fresh fuel. 4 56 THE HEATER REMAINS BURNING LOW Wick position too low. Reinstall the wick height lock (Section F). Before you refilled the tank, the heater had burnt up almost all the fuel. After having refilled and replaced the removable tank, wait for 30 minutes before igniting the heater. You are using the incorrect type of fuel. Refer to THE RIGHT FUEL (Section 'What you need to know in advance'). Leave a window or a door wide open for a while. [. . . ] 8 Remove the screw on the stem holding the bracket and remove the bracket, spring and wick height lock. 9 Turn right the stem to the end and remove the wick 6 7 sleeve (with wick). 8a 8b 10 Lift the wick sleeve up and remove it from the primary air tube. 11 Squeeze the wick to loosen the three wick pins and remove the wick from the wick sleeve. Ensure that you are wearing gloves and that you have a container in which to put the old wick. 9 10 11 4 60 12a 12b 12 Install the wick to the wick sleeve according to the allowed direction engraved on the wick sleeve. 13 Install the wick sleeve (with wick) to the primary air tube. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZIBRO R 45 C

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ZIBRO R 45 C will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag