Dear Sir, Madam,
Congratulations on the purchase of your airconditioner. You have acquired a high quality product that, if used responsibly, will give you many years of pleasure. Please read these instructions for use first in order to ensure the maximum life span of your airconditioner. On behalf of the manufacturer, we provide a 24-month guarantee on all material and production defects. [. . . ] If you set a low temperature for dry operation, you may feel the air flow is cold. During dry mode operation, the system performs the cooling operation until the room temperature reaches 1~2C above the setting temperature. Then it continues dry mode operation intermittently with fan speed at "LO", regardless of the designated speed. During dry operation, the indoor unit stops operating for 3 minutes when the room temperature reaches the setting temperature. During the heating operation, the outdoor unit may frost and heating capacity may be reduced. In this case, the unit stops its heating operation and conducts defrosting operation automatically. During the defrosting operation, the fans of the indoor and outdoor units stop. Unless the heat exchanger gets warm enough, the air will not flow out to prevent cold air.
Automatic operation
In automatic operation the air conditioner selects the operation mode (cooling, dry, heating) according to the room temperature when it starts.
The air conditioner will restart in the previous mode if automatic operation is resumed within 3 hours from the switch-off. The computer checks and compares the room temperature regularly after the compressor shuts off, and will adapt the operating mode.
4
27
1. 4.
Press the ON/OFF button Set the operation mode to Automatic "AUTO", by pressing the operation mode button Adjust the setting temperature by pressing the temperature setting buttons. Adjust the fan speed by pressing the fan speed button. When the mode is set at "AUTO" the fan speed changes automatically.
NOTE
If the selected mode by Automatic operation does not suit you, set the operation mode (cooling, dry, heating) with the operation mode button.
Negative ion operation
This function is available only when the air conditioner is operating.
1. 2.
Press the ON/OFF button Press the ionizer button
To stop negative ion operation, press the ionizer button.
4
28
Air flow adjustment
Horizontal adjustment When the ON/OFF button is pressed, the horizontal louver will move automatically.
During cooling, dry operation During circulation, heating operation
Level Approx. The timer lamp of the indoor unit goes off.
4
30
"OFF Timer" Example: Set the "Off Timer" to 10 p. m. Press the "TIME ADJ" 3 times.
2.
Adjust the time with the
button. The time setting changes in 10-minu-
te intervals. Hold the button to fast forward the time.
3.
Press the "TIME ADJ" button once. The setting of "OFF Time" is complete and the present time appears.
4.
Press the timer fixing button "ON". The "ON Time" is displayed for 2 seconds and then the present time appears.
Cancelling "OFF Timer" Press the timer fixing button "OFF". The timer lamp of the indoor unit goes off.
"SLEEP Timer" Pressing this button starts the timer mode that will stop the operation after the setting time.
Press the "SLEEP" button during the operation. The setting time repeats the following mode by pressing the button:
Continuous operation (Sleep Operation: OFF). The operation stops after passing the setting time.
4
31
Sleep Timer features During Cooling Operation The setting temperature rises 0. 6C after 30 minutes of Sleep Timer ON, and rises 0. 6C again after 30 minutes of the first temperature rise. [. . . ] The indicator light will go out within 10 minutes and the unit will return to the heating mode. Make sure the remote control is correctly aimed at the control panel. Remote control signal not detected by control panel. Make sure the remote control is correctly aimed at the control panel. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ZIBRO S1635
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.