User manual ZOOM B91UT

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ZOOM B91UT. We hope that this ZOOM B91UT user guide will be useful to you.

Lastmanuals help download the user guide ZOOM B91UT.


Mode d'emploi ZOOM B91UT
Download
Manual abstract: user guide ZOOM B91UT

Detailed instructions for use are in the User's Guide.

[. . . ] Operation Manual © ZOOM Corporation Reproduction of this manual, in whole or in part, by any means, is prohibited. 0804B9E. indb 1 08. 4. 25 10:57:10 AM Safety Precautions / Usage Precautions SAFETY PRECAUTIONS In this manual, symbols are used to highlight warnings and cautions for you to read so that accidents can be prevented. The meanings of these symbols are as follows: This symbol indicates explanations about extremely dangerous matters. If users ignore this symbol and handle the device the wrong way, serious injury or death could result. This symbol indicates explanations about dangerous matters. [. . . ] When the module is set to off, the value 0 of the control change number is sent. ● When bypass/mute on/off switching is performed When bypass/mute is set to on, the value 127 of the control change number is sent. When bypass/mute is set to off, the value 0 of the control change number is sent. bypass/mute is switched off. If control change value is between 64 and 127, bypass/mute is switched on. Sending pedal synth playing information via MIDI (note on/note off) When the pedal synth function is enabled, foot switch playing information can be sent as note on/note off messages via MIDI ■ Example for receiving control change messages (1) When a control change message is received. . . MIDI IN connector MIDI OUT connector 1. In manual mode or play mode, press the [SYSTEM] key. 2. Turn the [TYPE] knob to bring up the "NOTE ON Tx" (send note on/ note off) parameter on the display. (2) The same operation as when the respective expression pedal or switch or key at the B9. 1ut is operated occurs. [TYPE] knob According to the control change value received, the B9. 1ut status and parameter values change as follows. ● When control change for built-in/ external expression pedal is received The value of the parameter assigned to the pedal changes according to the control change value (0 – 127). ● When control change for module on/ off is received If control change value is between 0 and 63, the module is switched off. If control change value is between 64 and 127, the module is switched on. ● When control change for bypass/mute on/off is received If control change value is between 0 and 63, 3. Turn parameter knob 1 to select "ON" or "OFF". When ON was selected, playing with the pedal synth function will result in note on/note off messages being sent. The pedal synth function has two operation modes for producing sound: TG (trigger) and HD (hold). The differences in note on/note off sending operation are as follows. ● TG Note on is sent when the foot switch is pressed and note off is sent when the foot switch is released. ● HD Note on is sent when the foot switch is ZOOM B9. 1ut 49 0804B9E. indb 49 08. 4. 25 10:58:43 AM MIDI Usage Examples pressed, and note off is sent when the foot switch is pressed once more. using a MIDI cable. MIDI IN MIDI OUT MIDI IN MIDI OUT HINT For more information on the pedal synth function, see page 55. 4. When the setting is complete, press the [EXIT] key to cancel the SYSTEM menu. I f a set t i ng was cha nge d, t he i nd icat ion "Store. . . ?" appears on the display, to allow you to store the changes. If no setting was changed, the unit returns to the previous mode. The steps at the target B9. 1ut and source B9. 1ut are explained separately below. ■ Target B9. 1ut 5. Press the [STORE/SWAP] key to save the changes. The setting is accepted, and the unit returns to manual mode or play mode. By pressing the [EXIT] key, you can abort the changes and return to play mode without saving. 2. Set the B9. 1ut to manual mode or play mode. If the unit is in another mode or shows another display, press the [EXIT] key to return to the manual mode or play mode. HINT To send note on/note off information, make connections as shown in step 7 of "Assigning control change numbers" (→ p. Set the B9. 1ut to manual mode or Sending and receiving B9. 1ut patch data via MIDI The patch data stored in a B9. 1ut can be sent and received as MIDI messages (system exclusive). When two B9. 1ut units are connected via a MIDI cable, this allows copying of patch data from the sending unit to the receiving unit. play mode and press the [SYSTEM] key. 4. [. . . ] Click the Play button in the transport panel to start playback. NOTE • While the monitoring button is enabled, the direct signal input to this unit and the signal routed to the computer and then returned to this unit will be output simultaneously from this unit, causing a flanger-like effect in the sound. To accurately monitor the sound also while adjusting the recording level, temporarily set the output device port for the VST connection (step 6) to "Not Connected". • The level meter as in the above illustration shows the signal level after processing in this unit. When you pluck a guitar string the meter may register with a slight delay, but this is not a defect. HINT If no sound is heard when you click the Play button after recording, check the VST connection settings (step 6) once more. HINT The Inspector shows information about the currently selected track. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZOOM B91UT

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ZOOM B91UT will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag