User manual ZYXEL P-660HW-D1 STANDARD VERSION - 01-10-2007

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ZYXEL P-660HW-D1. We hope that this ZYXEL P-660HW-D1 user guide will be useful to you.

Lastmanuals help download the user guide ZYXEL P-660HW-D1.


Mode d'emploi ZYXEL P-660HW-D1
Download
Manual abstract: user guide ZYXEL P-660HW-D1STANDARD VERSION - 01-10-2007

Detailed instructions for use are in the User's Guide.

[. . . ] ZyXEL Confidential ZyXEL Firmware Release Note P-660HW-D1 Standard version Release 3. 40(AGL. 4)C0 Date: Author: Jan 10 , 2007 Ross Meng 340AGL4C0. doc 1/41 ZyXEL Confidential ZyXEL P-660HW-D1 Standard Version Release 3. 40(AGL. 4)C0 Release Note Date: Jan 10, 2006 Supported Platforms: ZyXEL P-660HW-D1 Versions: ZyNOS Version Bootbase Version : V3. 40(AGL. 4) | 01/10/2007 12:00:00 : V1. 06 | 1/20/2006 9:44:11 Notes: The P-660HW-D1, is 4th generation of ZyXEL ADSL product family. It is a high performance ADSL/ADSL2/ADSL2+ router for small/medium office to have Internet access and LAN-to-LAN application over the existing copper line. P-660HW-D1 takes advantage of much higher data rate than ADSL, speed up to 12Mbps (ADSL2) or 26Mbps (ADSL2+), greater reach, faster start-up, advanced diagnostics and better power management. This high performance ADSL router is a high integrated advanced Firewall, Bandwidth Management and IEEE 802. 11g wireless features to meet the demand of high-end market. [. . . ] Run ftp file transfer, after several hours, it will stop, when it stop, the LAN PC can't ping to the WAN PC's IP address (the ftp server). [BUG FIX] SPRID: 060222092 Symptom: DUT will crash when issue CI command "sys server disp". Issue CI command "sys server disp", the DUT will crash. [BUG FIX] SPRID: 060110441 Symptom: (bug fixed not complete) help page issue. Advanced-Network-WAN-Internet Access Setup, help page is not right. Advanced-Maintenance-tools-configuration can't get the help page. 340AGL4C0. doc 13/41 ZyXEL Confidential 33. [BUG FIX] SPRID: 060224160 Symptom: DNS page in Remote Management seems useless. Condition: DNS page in Remote Management seems useless step1. In eWC, go to "Advanced > Remote MGNT > DNS" to configure, "Access Status: LAN" and click "Apply" button. One PC at WAN side, configure DNS as DUT's WAN IP. Let PC ask DUT DNS, for example, ping tw. yahoo. com. No matter what configuration, DUT still reply DNS, seems the DNS page doesn't work. [BUG FIX] SPRID: 060224161 Symptom: SMTP send log mail schedule issue. GUI, Maintenance > Logs > Log Settings page step2. The log Schedule function does not work. It always send log mail immediately when a log is create. [BUG FIX] SPRID: 060224162 Symptom: Block intraBSS: We load the default setting, then config static WEP128 environment. We prepare three wireless client(Centirno-G/G-162/B-220) to associate Router/AP and ping each other. If we change the 802. 11mode of the page "wireless advanced setup" from "Mixed" to "802. 11g", then three wireless clients can not ping each other. (But the three wireless client still can ping Router/AP) 36. [BUG FIX] SPRID: 060224165 Symptom:When client is Intel Centrino 2100 3b, it can not connect to AP. When client is Intel Centrino 2200 BG, it can not connect to AP at WPA/WPA2 mode. Condition: When client is Intel Centrino 2100 3b, it can not connect to AP. When client is Intel Centrino 2200 BG, it can not connect to AP at WPA/WPA2 mode. [BUG FIX] SPRID: 051223420 Symptom: in the page with form, do some setting in the modify page, then return the page, some times it have changed. [. . . ] The range is between 0 (the lowest) to 7 (the highest). The priority is unchanged if the user doesn't set a new value. The class can borrow bandwidth from its parent class when the borrow is set on, and vice versa. The borrow is unchanged if the user doesn't set a new value. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZYXEL P-660HW-D1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ZYXEL P-660HW-D1 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag